or 4B, POWER CORD CONNECTIONS
(3-Wire Connection
Instructions,
For existing
installations ONLY
- Refer to Fig. 13).
1.
Follow
the manufacturer's
installation
instructions
supplied
with the
strain relief and install (Also see Figs. 9, 10 & 1 1).
2.
Insert the end connectors
for Line 1, Line 2 and Neutral
and tighten
securely
to the terminal
block
(See Fig. 13).
IMPORTANT
NOTE:
DO NOT LOOSEN
the factory
installed
nut
connections
which
secure
the range wiring
to the terminal
block.
Electrical
failure
or loss of electrical
connection
may occur if these 3
nuts are loosened
or removed.
3.
Make sure all connections
are tightened
securely
and replace
the rear
access
cover (See Fig. 9).
Grounding
Instructions (3-Wire Connections
only):
A ground
strap
is installed
on this range which
connects
the center
terminal
of the
terminal
block (Neutral)
to the range chassis.
The ground
strap is
connected
to the range by the center,
lowest
screw
(See Fig. 13). The
ground
strap must not be removed
unless
National,
State or Local
Codes
do not permit
use of a ground
strap.
NOTE:
If the ground
strap is removed
for any reason,
a separate
ground
wire must be connected
to the separate
ground
screw
attached
to the range chassis
and to an adequate
ground
source.
4c. 3 & 4-WIRE
PERMANENT
WIRE
CONNECTIONS.
3 - Wire
Permanent
Connection
- follow
Steps
1,2 & 5 below.
4 - Wire
Permanent
Connection
- follow
Steps
I thru 5 below.
Before
wiring
the range,
review the suggested
power
source
location
drawings
in Fig. 3. If connecting
to a 4-Wire
electrical
system
(new branch-
circuit
or mobile
home
requires
4-Wire
connection):
1.
(3 & 4 - Wire
Permanent
Connections)
Follow
the manufacturer's
installation
instructions
supplied
with the strain relief and install.
2.
(3 & 4 - Wire
Permanent
Connections)
Strip insulation
away from the
ends of the permanent
wiring
for Line 1, Line 2, Neutral
(also strip ground
wire on 4-Wire
Connections).
Tighten
all 3 wire leads to the terminal
block (Follow
wire locations
shown
in Fig. 14).
IMPORTANT
NOTE:
DO NOT LOOSEN
the factory
installed
nut
connections
which
secure
the range wiring
to the terminal
block.
Electrical
failure
or loss of electrical
connection
may occur
if these 3
nuts are loosened
or removed.
NOTE:
For 3-Wire
Permanent
Connections
skip
Steps
3 & 4 and continue
with
Step
5.
3.
(4-Wire
Permanent
Connection
ONLY)
Disconnect
the ground
strap.
Remove
the factory
installed
ground
screw
& plate to release
the factory
installed
copper
ground
strap from frame of the appliance.
Cut and
discard
the copper
strap from the terminal
block.
KEEP the ground
screw,
ground
plate and go to Step 4.
4.
(4-Wire
Permanent
Connection
ONLY)
Connect
the ground
wire lead
(Green)
to the frame
of the appliance
using the ground
screw
& plate as
shown
in Fig. 15. Be sure to install using the same
hole in the frame
where the ground
screw was originally
installed.
5.
(3 & 4 - Wire
Permanent
Connections)
Make sure all connections
are
tightened
securely
and replace
the rear access
cover (See Fig. 9).
NOTE:
Non-terminated
field wire compression
connections
must be
set at approximately
35 in./Ibs.
5. CAREFULLY
SLIDE
RANGE
INTO
FINAL
LOCATION.
Be sure
to provide
all the adequate
clearances
and dimensions
shown
in Figs. 1, 2 & 3 before
moving
range into final location.
Carefully
slide range into final position while inserting
rear leveling leg
into and FULLY ENGAGING
THE ANTI-TIP
BRACKET
(See Fig. 7).
Make sure the power
cord folds into the remaining
open floor area
behind
the range
Warmer
or storage
drawer.
Be sure to check
the
level of the range.
4
3-Wire
Connection
Factory installed connections (DO NOT LOOSEN)
Terminal
Connect
Line 1
here
Connect
Neutral
(White or
Center) here
Connect
here
NOTES:
Install
Strain-Relief
Bushing,
Center
or white
wire must
always
be
attached
to the center
terminal
on block.
Fig. 13
FOR 3 & 4-Wire Permanent
Connections
_TIGHTEN
ALL 3 WIRE
LEADS
STRAP
4--GROUNDPLATE
GROUND
sc. w
4-Wire Permanent Connection
ONLY
Fig. 14
GROUND
GROUND
GROUND
SCREW
WlRE LEAD
PROPER
GROUND FOR
4-WIRE
Ib
PERMANENT

Advertisement