Miele DA 6520 W Operating And Installation Instruction
Miele DA 6520 W Operating And Installation Instruction

Miele DA 6520 W Operating And Installation Instruction

Hide thumbs Also See for DA 6520 W:

Advertisement

Quick Links

Operating and Installation
Instructions
Ventilation System
DA 6590 W
DA 6520 W
en - US
To prevent accidents
and appliance damage,
read these instructions
before
installation or use.
M.-Nr. 09 523 600

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA 6520 W

  • Page 1 Operating and Installation Instructions Ventilation System DA 6590 W DA 6520 W en - US To prevent accidents and appliance damage, read these instructions before installation or use. M.-Nr. 09 523 600...
  • Page 2: Table Of Contents

    Contents IMPORTANT SAFETY INSTRUCTIONS....... . . 3 Description of functions ..........7 Guide to the ventilation system .
  • Page 3: Important Safety Instructions

    Use this appliance only in the manner intended by the manufacturer. Read these instructions carefully If you have questions, contact Miele. before installing or using the b) Before servicing or cleaning the Ventilation System. appliance, switch power off at the...
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS d) Before connecting the appliance to the power supply make sure that the ,WARNING voltage and frequency listed on the data plate correspond with the TO REDUCE THE RISK OF A household electrical supply. COOKTOP GREASE FIRE: This data must correspond to prevent appliance damage.
  • Page 5 IMPORTANT SAFETY INSTRUCTIONS ,WARNING Do not allow children to play with or operate the appliance or its controls. TO REDUCE THE RISK OF Supervise its use by the elderly or INJURY TO PERSONS IN THE infirm. EVENT OF A COOKTOP Always turn on the hood when using GREASE FIRE, OBSERVE THE the cooktop to prevent damage from...
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS Installation g) Do not install this hood over cooktops that burn solid fuel. ,WARNING h) Provided a larger distance is not TO REDUCE THE RISK OF given by the manufacturer of the FIRE, ELECTRIC SHOCK, OR cooktop, follow the minimum safety distances between a cooktop and the INJURY TO PERSONS, bottom of the hood given in the...
  • Page 7: Description Of Functions

    Description of functions The ventilation system can be operated Air extraction Recirculation mode The recirculation mode requires a The air is drawn in and cleaned by the conversion kit and odor-free filter grease filters and directed outside. (optional accessories for the The hood comes equipped with a DA 6590 W only, see "Technical data") non-return flap.
  • Page 8: Guide To The Ventilation System

    Guide to the ventilation system...
  • Page 9 Guide to the ventilation system Chimney extension Filter button The indicator l of the grease filter Chimney button lights when the grease filters Canopy need to be cleaned. Control panel The odor-free filter symbol — comes Grease filter on when the odor-free filter (for recirculation mode) needs to be Glass or stainless steel panels replaced.
  • Page 10: Operation

    Operation Turning the fan on K Automatically switching back from the IS setting ^ Press the On/Off button K. The intensive level can be programmed The fan turns on at level 2. The K to automatically switch back to level 3 symbol and power level 2 indicators after 10 minutes.
  • Page 11: Delayed Shut Down 5 ¢15

    Operation Delayed shut down 5 ¢15 Overhead lighting I For both air extraction and recirculation, Turning the overhead lighting on it is recommended that run the fan for several minutes after cooking is The overhead lighting and the fan can completed.
  • Page 12: Filter Timer

    Operation ^ Press the On/Off button K to turn the Automatic safety shut-off fan off The fan will turn automatically off 10 ^ Press the delayed shut down button hours of use. The lighting however will 5 ¢15 and the filter button [— at remain on.
  • Page 13 Operation Activating/changing the odor-free filter Checking the filter operating hours timer — counter (in recirculation mode) Even before the maximum operating time has been reached, you can check The odor-free filter is necessary for what percentage of the time has recirculation mode.
  • Page 14: Cleaning And Care

    Cleaning and care ,WARNING Avoid: TO REDUCE THE RISK OF – cleaning agents containing soda, FIRE, ELECTRIC SHOCK, OR acids or chlorides, INJURY TO PERSONS, – abrasive cleaning agents OBSERVE THE FOLLOWING: e.g. powder or cream cleansers, – abrasive sponges, e.g. pot scourers Before cleaning or servicing the or sponges which have been hood, disconnect it from the power...
  • Page 15: Glass Or Stainless Steel Panels And Grease Filters

    Cleaning and care Glass or stainless steel panels Special instructions for glass surfaces and grease filters ^ Glass surfaces should be cleaned The glass or stainless steel panels and with a normal glass cleaner. the reusable metal grease filters remove solid particles from the vented Stainless steel colored controls kitchen air (grease, dust, etc.) and prevent soiling of the hood.
  • Page 16 Use a wash program with a max. temperature of 150°F (65°C). In a Miele dishwasher use the "Normal" program. Use the recommended amount of dishwasher detergent. Overuse could destroy the filter.
  • Page 17: Resetting The Grease Filter Timer

    Cleaning and care ^ When reinstalling the grease filters, Resetting the grease filter timer make sure that the locking clips are After cleaning, reset the grease filter facing down. timer. ^ With the fan running, press and hold the grease filter button l— for approx.
  • Page 18: Installing / Replacing The Odor-Free Filter

    – when the filter no longer absorbs Replacement active charcoal filters odors efficiently. can be ordered from Miele. However, it should be changed at least ^ To install or replace the odo-freer every 6 months. filter, the grease filters must first be...
  • Page 19: Changing The Light Bulbs

    Cleaning and care Changing the light bulbs ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before changing the light bulbs, disconnect the hood from the power supply, see "Important Safety Instructions". When in use halogen bulbs become extremely hot, and can burn your hands.
  • Page 20: After Sales Service

    Miele’s Service department, Extended Service Contracts offered by other providers for Miele products will not be recognized by Miele. Our goal is to prevent unauthorized (and untrained) service personnel from working on your Miele products, possibly doing further damage to them, you and/or your home.
  • Page 21: Installation Instructions

    Installation Instructions Read these instructions and the "Important Safety Instructions" before installing this ventilation system. The installation steps are described in the enclosed "Installation Diagram". Leave these instructions with the appliance for the consumer/user. Information is subject to change. Please refer to our website to obtain the most current product specification, technical &...
  • Page 23: Caring For The Environment

    Caring for the environment Disposal of packing material Disposal of an old appliance The cardboard box and packing Old appliances may contain materials materials protect the appliance during that can be recycled. Please contact shipping. They have been designed to your local recycling center about the be biodegradable and recyclable.
  • Page 24: Appliance Dimensions

    Appliance dimensions Drawing is not to scale.
  • Page 25 Appliance dimensions Air extraction mode Recirculation mode Recirculation vent positioned at the top (only for the DA 6590 W in recirculation mode) Installation area; For recirculation mode only Wall/ceiling area respectively for vent hole and outlet installation. For recirculation mode only the outlet installation is required.
  • Page 26 Do not install this exhaust hood over cooktops burning solid fuel. Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood: Miele Cooktops Non-Miele Cooktops Electric Cooktops 24"...
  • Page 27 Appliance dimensions Drilling diagram To prepare a backing plate, the spacings for the 5 mm screws need to be drilled as shown. If the ventilation hood will be mounted directly to the wall, follow the additional instructions given in the included "Installation diagram".
  • Page 28: Plywood Backing

    Plywood backing ^ Find the studs to the left and right of The majority of the weight of the the mounting location by tapping the installed ventilation system will be wall or using a stud finder. supported by the lower retaining ^ Mark a vertical cutting line along the plate.
  • Page 29: Installation

    Installation Dismantling Before installation read the If the hood needs to be disassembled, information in the "Dimensions" and follow the instructions on the "Important Safety Instruction" "Installation diagram" in the reverse chapters. order. Under certain conditions, there is a A lever is enclosed for easier removal danger of poisonous fumes by when the ventilation system and a furnace of the chimney extension.
  • Page 30: Installation Material

    Installation Installation material...
  • Page 31 Installation 3 protective shields to prevent scratches to the chimney during installation. 2 M 6 locking nuts 1 vent collar for securing the motor assembly. for use with 6" (150 mm) exhaust ducting. 1 vent pipe adapter for use with 5" (125 mm) exhaust 2 Screws 3.9 x 7.5 mm ducting.
  • Page 32: Air Extraction

    Air extraction Exhaust ducting and connections WARNING Use smooth or flexible pipework made from approved non-flammable Danger of toxic fumes. materials for exhaust ducting. Gas cooking appliances release To achieve the most efficient air extraction and quietest noise levels, carbon monoxide that can be consider the following: harmful or fatal if inhaled.
  • Page 33 Air extraction – If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. Never connect an exhaust hood to an active chimney, dryer vent, flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent...
  • Page 34: Reducing Collar

    Air extraction Reducing Collar Condensate trap (optional accessory) (optional accessory) If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the In some cases, a condensate trap may Reducing Collar can be installed. also be required to collect and evaporate any condensate which may It reduces the air flow to less than...
  • Page 35: Electrical Connection

    If there is any question concerning the electrical connection of this appliance to your power supply, please consult a licensed electrician or call Miele’s Technical Service Department. ,WARNING: THIS APPLIANCE MUST BE GROUNDED...
  • Page 36: Technical Data

    ....6.5 ft (2 m) Weight DA 6590 W ... 46 lbs (21 kg) Optional accessories for recirculation (DA 6590 W only): – DUW 20 conversion kit – Miele DKF 12-1 active carbon filter...
  • Page 40 Alteration rights reserved / 5012 M.-Nr. 09 523 600 / 01 INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION.

This manual is also suitable for:

Da 6590 w

Table of Contents