[-_Do
not damage the air cooler!
Clean with warm water only; do
not use hard/sharp-edged
objects!
7. Clean the air cooler completely,
drain thoroughly.
8. Clean the seals.
Cleaning the moisture
sensor
Occasionally
the moisture
sensor
has to be cleaned because a fine
layer of transparent
buildup is
deposited
on the sensors.
C
Changing
the light
bulb
The dryer light turns on inside the
drum when you open the door.
To change the light bulb:
1. Turn off the circuit breaker.
2. Pull out power supply plug.
3. Open the door and locate the
light bulb on the upper center
of the seal.
9. Re-insert
the air cooler, handle
at the bottom!
10. Unscrew
both locking levers.
1. Close the maintenance
flap
until it locks into position.
This deposit can easily be removed
by wiping the sensors (the two bars
next to the lint filter) with a cloth and
a little white vinegar.
Use white vinegar only!
Clean the moisture
sensor once
a month.
Cleaning the bearing
shield
Over time, fluff from the drying
process
collects in the bearing
shield
4. Loosen the screw of the cover
and open the cover.
5. Turn bulb counterclockwise.
Replace the bulb with a new
appliance
bulb only (obtainable
through
customer
service).
6. Replace the cover and secure
with the screw.
7_
Plug in dryer or reconnect
power supply.
This fluff can be easily removed
using your vacuum cleaner, at least
once a month.