INSTALLATION
INSTRUCTIONS
17
Venfing
the dryer
AWARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance,
follow basic precautions,
including
the following:
. Do not crush or collapse
ductwork.
Failure to follow these
. Rigid or semirigid
metal ducting
is recommended
for use
instructions
can result in fire or death.
. Do not allow
ductworkto
rest on or contact sharp objects.
Failure to follow these instructions
can result in fire or death.
. If connecting
to existing
ductwork,
make sure it is suitable
and clean before
installing
the dryer. Failure to follow these
instructions
can result in fire or death.
. Venting must conform to local building codes. Failure to follow
these instructions can result in fire or death.
. Gas dryers MUST exhaust
to the outdoors.
Failure to follow these instructions
can result in fire or death
. Use only 4-inch (10.2 cm) rigid or flexible metal ductwork
inside the dryer cabinet and for venting outside. Failure to
follow these instructions can result in fire or death.
. To reduce the risk of fire, combustion, or accumulation
of
combustible
gases, DO NOT exhaust dryer air into an enclosed
and unventilated area, such as an attic, wall, ceiling, crawl
space, chimney, gas vent, or concealed space of a building.
Failure to follow these instructions can result in fire or death.
between the dryer and the wall. in special installations
when it is impossible to make a connection with the above
recommendations, a UL=listed flexible metal transition
duct
may be used between the dryer and wall connection only.
The use of this ducting will affect drying time. Failure to follow
these instructions can result in fire or death.
DO NOT use sheet metal screws or other fasteners which
extend into the duct that could catch lint and reduce the
efficiency of the exhaust system. Secure all joints with duct
tape. Failure to follow these instructions can result in fire or death.
To maximize operating results, please observe the duct length
limitations
noted in the chart next page. Failure to follow these
instructions can result in fire or death.
Ductwork is not provided with the dryer. You should obtain
the necessary ductwork
locally. The end cap should have
hinged dampers to prevent backdraft when the dryer is not in
use. Failure to follow these instructions can result in fire or death.
The Total length of flexible metal duct shall not exceed 8 ft.
(2.4 m)
. To reduce the risk of fire, DO NOT exhaust the dryer with
plastic or thin foil ducting.
Failure to follow these instructions can result in fire or death.
. The exhaust
duct must be 4 inches (10.2 cm) in diameter
with
no obstructions.
The exhaust duct should be kept as short as
possible. Make sure to clean any old ducts before
installing
your new dryer.
Failure to follow these instructions
can result in
fire or death.
In Canada,
that only those foil-type
flexible
ducts,
if any,
specifically
identified
for use with the appliance
by the
manufacturer
shall be used. In the United States, that only those
foil-type
flexible ducts, if any, specifically
identified
for use with
the appliance
by the manufacturer
and that comply
with the
Outline for Clothes DryerTransition
Duct, Subject 2158A, shall be
used.