Download Print this page

Kenmore 2671532 Use & Care Manual page 22

Gas laundry center
Hide thumbs Also See for 2671532:

Advertisement

Available languages

Available languages

Minimum
Clearance
Other
Than Alcove
or
Closet
hsstallation
No clearances
to combustible
surfaces and for air opening
are needed on both sides, nor to the rear of the appliance.
Consideration
must be given to provide
adequate
clearance
for installation
and service.
1_ Preparing
for
installation
of new appliance
DISCONNECTING
GAS
Turn gas
Shut-Off
valve
I(_'_'_f,_
to the Off
p°siti°nx,
x_
_
Disconnect and discard old
flexible
gas connector
and
old transition
ducting
material.
I --
I
Replace with new CSA(AGA)
I
I
approved
flexible
gas line I
I
connector
and UL approved
I
I
transition
duct.
NEVER
REUSE OLD
FLEXIBLE CONNECTORS.
The use of old flexible
connectors
can cause leaks and per-
sonal injury. Always
use new flexible
connectors
when install-
ing gas appliances.
REMOVING
LINT FROM WALL EXHAUST OPENING
• Remove and discard
existing
plastic or metal
foil transition
duct and replace
with UL listed transition
duct.
Internal
duct
Wall
Check
that
exhaust
hood
damper
opens
and closes
freely.
Move appliance
close to final
position. Make
sure there is at
least a 24" clearance
on right
side of it to remove shipping
bar.
PULL SHIPPING
BAR OUT US-
ING YELLOW
PLASTIC HANDLE.
Keep bar so it can be reinstalled
if the appliance
is ever moved
again.
Shipping
Bar
Yellow plastic handle
NEW HOME
OR REMODELING
FAUCETS/DRAIN
STANDPIPE/ELECTRICAL
LOCATION
Right side of
Laundry Center
Locate
spigots,
drain standpipe
and electrical plug
in this area
m
,
4k
42"
133"
Floor
2 Gas requirements
TILT THE APPLIANCE
SIDEWAYS AND
REMOVE THE FOAM
SHIPPING
PADS
BY PULLING
AT THE SIDES AND
BREAKING
THEM AWAY FROM THE
APPLIANCE
LEGS. BE SURE TO RE-
MOVE
ALL OF THE FOAM
PIECES
AROUND
THE LEGS.
After the machine
is in the home,
remove remaining
packing
mate-
rial/carton
from washer. DO
NOT REMOVE SHIPPING
ROD
AT THIS TIME. Remove styrofoam
block. Remove the bag contain-
ing the Washer
hoses and parts
from tub. Put styrofoam
block
back in tub opening
to hold tub
in place during
the rest of instal-
lation.
Styrofoam
Block
hoses
and parts
• Installation
must conform
to local codes and ordinances,
or
in their absence, the NATIONAL
FUEL GAS CODE, ANSI
Z223.
• This gas dryer is equipped
with a Valve
& Burner Assembly
for use only with natural
gas. By using conversion
kit
WE25M74
for 27" Models, your local service organization
can convert this dryer for use with propane
(LP) gas. ALL
CONVERSIONS
MUST BE MADE BY PROPERLY TRAINED
AND QUALIFIED
PERSONNEL AND IN ACCORDANCE
WITH
LOCAL CODES AND ORDINANCE
REQUIREMENTS.
• The appliance
must be disconnected
from the gas supply
piping
system during any pressure testing of that system at
a test pressure in excess of 0.5 PSI (3.4 KPa).
• The appliance
must be isolated
from the gas supply
piping
system by closing
the equipment
shut-
off valve during any
pressure testing
of
the gas supply pip-
ing of test pressure
equal to or less than
0.5 PSI (3.4 KPa).
Gas Supply
Connection
3"
22

Advertisement

loading