Table 6.1 shows the meaning of the response data and its code (indicated in
hexadecimal).
Response data
ACK (Acknowledge)
Reception
Parity error
error
Flaming error
Overrun error
Count error
6.2
Command/Response Format
The command/response format is as follows.
CNT
(1)
CNT (count) field
The total number of bytes in the command/response to be transmitted is
represented.
(2)
CMD/RPS field
A command or response code is indicated.
(3)
TEXT field
Additional information for a command or response, called control or device
information, is indicated.
(4)
Additional field
In some commands, additional field exists next to TEXT field.
Table 6.1 Response data
Meaning
A command or response has been received
normally.
A parity error has been detected in received
data.
A flaming error or an overrun error has
been detected in received data.
The byte count for the command or
response does not match the number of
bytes transferred.
CMD/RPS
TEXT
50FH5037E>02
Code (Hex)
Additional field
©FFπ
©80π
©81π
©82π