2.1.3
Environmental and power requirements
Table 2.3 lists the environmental and power requirements.
Table 2.3
Item
Power
Average
requirements
Power
consumption
Ready
Random seek, read/ or write
Power save mode
Pre-idle mode
Idle mode
Standby mode
Sleep mode
With panel
Dimensions
(W"D"H)
Without panel
Weight
Environmental
Operating
requirements
Idle
Transport
Installation
Tilt angle
Vibration/
Operating
shock
Idle
No cartridge, power ON
Transport
Environmental and power requirements (1 of 2)
+5 VDC±5%, 1.1 A (2.5 A Max.) (*1)
Ripple requirement 100mV P-P (DC-1 MHz)
MCE3130AP
3.9 W (typical) (*2)
5.5 W (typical) (*2)
3.40 W (typical) (*2)
2.00 W (typical) (*2)
0.65 W (typical) (*2)
0.65 W (typical) (*2)
101.6"150.0"25.4 mm
101.6"148.4"25.4 mm
480 g (with panel)
Temperature:
Relative humidity: 10 to 85% (Noncondensing)
Max. wet bulb temperature: 29°C or lower
Temperature:
Relative humidity: 10 to 85% (Noncondensing)
Max. wet bulb temperature: 36°C or lower
Temperature:
Temperature:
Relative humidity: 5 to 90% (Noncondensing)
Max. wet bulb temperature: 41°C or lower
Requirement: Packing conditions specified by Fujitsu
–5° to +10° (*3)
3.92 m/s
Shock 19.6 m/s
9.8 m/s
Shock 49 m/s
Shock 490 m/s
Requirement: Packing conditions specified by Fujitsu
C156-E142-02EN
Specification
MCE3064AP, MCF3064AP
3.9 W (typical) (*2)
5.3 W (typical) (*2)
3.40 W (typical) (*2)
2.00 W (typical) (*2)
0.65 W (typical) (*2)
0.65 W (typical) (*2)
5 to 45°C (*3)
(gradient 15°C /h or less)
0 to 50°C
–40 to 60°C (24 hours or less)
–20 to 60°C (24 hours or more)
2
(0.4 G [5 to 500 Hz, sine sweep])
2
(2 G [10ms, half-sine pulse])
2
(1.0 G [5 to 500 Hz, sine sweep])
2
(5 G [10 ms, half-sine pulse])
2
(50 G [10 ms, half-sine pulse])
2 - 7