N8800-128F, EXP320J NEC Express5800/320Fd-LR N8800-129F, EXP320K NEC Express5800/320Fd-MR User's Guide (Setup) 2nd Edition 9-2008 856-127506-112- B...
Page 2
The NEC product(s) discussed in this document are warranted in accordance with the terms of the Warranty Statement accompanying each product. However, actual performance of each such product is dependent upon factors such as system configuration, customer data, and operator control.
Page 3
Keep this User's Guide handy for quick reference when necessary. Safety Indications To use NEC Express5800 series safely, follow the instructions in this User's Guide. This guide explains components that pose a danger, types of dangers caused by failing to follow the instructions, and actions taken to prevent them;...
Page 4
Symbols and its descriptions used in this User’s Guide and warning labels are as follows: Attention Indicates a risk of an electric shock. Indicates a risk of a personal injury due to heat. Indicates a risk of catching your fingers. Indicates a risk of a fire or smoke.
Page 5
Mandatory actions Unplug the server. There is a risk of an electric shock or fire. Indicates a general action to take that is not defined herein. Make sure to follow the instructions. For detailed notes to set up the machine safely, refer to “NOTES FOR SAFE HANDLING” on page 1-2.
Page 9
Trademarks and Patents NEC EXPRESSBUILDER, NEC ESMPRO and DianaScope are registered trademarks of NEC Corporation. Microsoft, Windows, Windows Server, Windows NT, and MS-DOS are registered trademarks of Microsoft Corporation in the United States and other countries. Intel and Pentium are registered trademarks of Intel Corporation.
Page 10
(5) NEC assumes no liability arising from the use of this product, nor any liability for incidental or consequential damage arising from the use of this manual regardless of (4) above.
“high performance,” “scalability,” and “general versatility” provided by NEC Express5800 series. In the event of trouble, its dual configuration will allow the system to instantaneously isolate the failed parts to assure non-stop running; operation will be moved smoothly from one module to the other, minimizing damage to it.
Something you need to make sure when using the server or software Helpful information, something useful to know TIPS: About our Web Service Information on NEC Express5800/ft series including modification modules is also available on our web site, NEC Express5800 Web Site Asia Pacific: http://www.nec.co.jp/express/index.html...
Page 14
關於正式文本 O• k c_ e‡ g, ÿ f/pº N † x º [ æ [ ‰ ˆ Ý g ,ˆ Ý • n ÿ € ý O • u (v„ • \ 0 • 2 ˆ L [ ‰ ˆ Ý v „ f BPŠ Ë R ) u( 0 O•...
Installing a Rack ..................3-2 Installing the Device to the Rack (N8140-74/92/93/94/98/99)....3-5 Unmounting the Device from the Rack (N8140-74/92/93/94/98/99)..3-12 Installing the Tower Conversion Kit (N8843-002)........3-13 Steps to Install the Rack-mount Model to the Tower Conversion Kit ..3-15 Connect Peripheral Devices to NEC Express5800/ft series........3-18...
Page 16
Step 4: Invalidate OS Boot Monitoring Function........4-12 Step 5: Set HBA Configuration by Emulex BIOS........4-16 Step 6: Install VMware ESX Server 3.0.2ft ..........4-22 Step 7: Install Software NEC Express5800/ft Series offers ..... 4-26 ft Server Control Software .............. 4-26 NEC ESMPRO Agent................ 4-27 Step 8: Connect and Configure Options ...........
Chapter 1 Before Using This chapter includes information necessary for proper and safe operation of the server, the main unit and its accessories. Go through this chapter before you start setup of the product.
Page 18
1-2 Before Using 在使用前 p º N † b Š g , ˆ Ý • n P Z p º [ ‰ Q h x º [ æ ‹ Š b O• u ( _ Å ‰ • v „ • Ü e ¼ O á ` o ÿ...
Before Using 1-3 NOTES FOR SAFE HANDLING The following section describes necessary information to use the product properly and safely. Warning Label Warning label is placed in the certain part of the system so that the user stays alert to possible risks. Do not remove or damage the label.
Page 20
1-4 Before Using 為了把有為了安全對待的注 意的本裝置做為安全確實變成使用必要的信息被記載。 關於警告標籤 隱藏實體內的危險性的零部件和那個週邊警告標籤被粘貼。這個是為了請操縱本裝置的時候, 經常在顧客裡(上)認識能考慮的危險性的東西(揭下標籤,請別弄髒)。如果這個標籤沒被粘貼, 剝落懸掛著,髒等做不能辨認的時候購買的銷售店請聯絡。 對以下表現被本產品粘貼的標籤的位置。 設備前部...
This equipment is not intended for use in controlling or use with facilities or systems where human lives are involved or high reliability is required, including medical devices or nuclear, aerospace, transportation, and traffic control facilities. NEC assumes no liability for any accidents or damage to physical assets resulting from the use of this equipment in such systems or facilities.
1-6 Before Using Use of Power Supply and Power Cord WARNING Do not handle power plugs with a wet hand. Do not plug/unplug power cords with a wet hand. There is a risk of an electric shock. Do not connect the ground wire to a gas pipe. Never connect the ground wire to a gas pipe.
: sulfur dioxide, hydrogen sulfide, nitrogen dioxide, chlorine, ammonia and/or ozone. Avoid installing NEC Express5800/ft series in a dusty environment or one that may be exposed to corrosive materials such as sodium chloride and/or sulfur.
1-8 Before Using Cleaning and Handling of Internal Devices WARNING Do not disassemble, repair, or alter the server. Unless described herein, never attempt to disassemble, repair, or alter the server. There is a risk of an electric shock or fire as well as malfunction. Do not look into the DVD-ROM drive.
Before Using 1-9 CAUTION Protect the unused connectors with the protective cap. The unused power cord connectors are covered with the protective cap to prevent short circuits and electrical hazards. When removing the power cord connector from the internal devices, attach the protective cap to the connector. Failure to follow this warning may cause a fire or an electric shock.
1-10 Before Using Rack-mount Model WARNING Do not install the server on a nonconforming rack. Install the server on a 19-inch rack conforming to the EIA standard. Do not use the server without a rack or install it on a nonconforming rack. The server may not function properly, and there is a risk of damage to physical assets or injuries.
Page 27
Before Using 1-11 CAUTION Do not install excessive wiring. To prevent burns, fires, and damage to the server, make sure that the rated load of the power branch circuit is not exceeded. For more information on installation and wiring of power-related facilities, contact your electrician or local power company. Do not pull out a device during operation.
Keep the accessories in a safe place. You will need them when you perform setup, addition of options, or replacement of failed components. To check NEC EXPRESSBUILDER components, see the attached list. Be sure to fill out and mail the software registration card that is shipped with the operating system.
2-2 About Operating System Vmware ESX Server 3.0.2ft When installing VMware ESX Server 3.0.2ft on the NEC Express5800/ft series, follow the procedure in “Setup procedure to install ESX Server” (page 4-3) to setup. Supported OS You need to install VMware ESX Server 3.0.2ft, hereinafter called as “ESX Server”, for using the NEC Express5800/ft series.
Chapter 3 Installing Server This chapter describes requirements for using the product properly and safely, the setup procedures to make NEC Express5800/ft series ready for use, and how to connect peripherals.
INSTALLATION This section describes installation of NEC Express5800/ft series. Rack-mount Model You can mount NEC Express5800/ft series on a rack that conforms to the EIA standards. IMPORTANT: NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to install it.
Page 43
Do not leave more than one device pulled out from the rack. Do not install excessive wiring. Do not install NEC Express5800/ft series in such places as listed below. If you locate racks or install the server in such places, the server may malfunction.
Page 44
3-4 Installing Server Place that is close to some equipment that causes power noises (e.g., sparks caused by power-on/off using a relay). If you must install the server close to such equipment, request your sales agent for separate power cabling or noise filter installation.
When the operating temperatures of NEC Express5800/ft series (10 to 35°C) are exceeded, there is a risk of malfunction. You must take adequate precautions and measures for airflow inside the rack as well as in the room so that the internal temperature can be kept within this range during operation.
Page 46
3-6 Installing Server Checking the place to install %Ï Imprinted mark Decide the place (height) to install. To keep imprinted marks for balance, install it as low as you can on the rack. 5Us) 4U (the height for To install the rack, the height for 4U is required. installing this device)
Page 47
Installing Server 3-7 If the rack has front and rear doors, read the instruction that comes with the rack, and open them. Install the brackets from the rear side of the rack. Install the brackets with its flat side facing inside.
Page 48
3-8 Installing Server Fix the core nuts to the front side of the rack. Attach them symmetrically (total: 8 core nuts). Core nuts (top of device) Bottom of device Core nuts Fix a core nut from inside of the rack. Hook either of the clips of the core nut to a square hole of the rack, and hook the other clip to a hole by a flat-blade screwdriver.
Page 49
Installing Server 3-9 Tentatively fasten the washers and plate Washers and plate screws (short) screws (short) to the 4 places on the front and back sides (total: 8) from the rear. Washers and plate screws (short) Fasten tightly the washers and round screws (long) to the 2 places on the left and right sides (total: 4) from the front.
Page 50
3-10 Installing Server Fasten tightly the 4 round screws on the back side and the 8 plate screws on the side panels (which you fastened tentatively). Panhead screws on the side panels Plate screws on the side panels Plate screws on the side panels Mount the CPU/IO module 0.
Page 51
Installing Server 3-11 Bring back the locks on the left and right sides. 10. Fasten the levers on the left and right sides with screws. 11. Mount the CPU/IO module 1 in the same way.
3-12 Installing Server Unmounting the Device from the Rack (N8140-74/92/93/94/98/99) Follow the steps below and unmount the device from the rack. CAUTION Observe the following precautions to use the server safely. There is a risk of a burn, personal injury, or damage to physical assets. For details, see “Notes for Safe Handling“...
Installing Server 3-13 INSTALLING the Tower Conversion Kit (N8843-002) This section describes how to install the rack-mount model of NEC Express5800/ft series without using the dedicated rack. IMPORTANT: NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to install it.
Page 54
3-14 Installing Server Do not install NEC Express5800/ft series in such places as listed below. Otherwise, the server may malfunction. Place where temperatures change widely (near a heater, air conditioner, or refrigerator). Place that is subject to intense vibration.
Installing Server 3-15 Steps to Install the Rack-mount Model to the Tower Conversion Kit Follow the procedure below to install the devices to the tower conversion kit. Open the front door of the tower conversion kit. If the door is locked, use the server-accessory key to unlock.
Page 56
3-16 Installing Server Fix the bracket with four washers and countersunk screws (long ones), two at the top and two at the bottom. Fix the bracket with 4 washers and countersunk screws. See the figure on the right for where to fix the screws (2 screws for the backside on the top, and 2 for the bottom of the tower conversion kit).
Page 57
Installing Server 3-17 Lock lever If it becomes rocked and cannot insert any further, push and keep the rock lever to the left as push the device further inside. Close the lever on the top and the bottom of the device. Fix the device to the bracket with clinchers.
To connect a third-party peripheral device or interface cable to the server, check with your sales agent to see if they are compatible with NEC Express5800/ft series. Some third-party devices may not be used with the server. ...
Page 59
Installing Server 3-19 IMPORTANT: Connection of optional devices In the case of standard configuration, you need to complete setup of the operating system before mounting optional PCI cards or hard disks that you purchased separately. If N8803-035 is mounted, be sure to connect cables to the FC array unit before going on to the next step.
Page 60
3-20 Installing Server Rotate the stopper clockwise, and insert the power cords to the AC inlets of the power unit. Connect the plug at the other end of the power cord to a wall outlet with parallel double-pole grounds provided or to an uninterruptible power supply (UPS).
ESX Server Setup 4-1 Chapter 4 ESX Server Setup This chapter describes procedures for configuring OS Boot Monitoring function, setting up for ESX Server installation, FC card setting, and so on.
Invalidate OS Boot Monitoring function Step 5: Set HBA configuration by Emulex BIOS Step 6: Install VMware ESX Server 3.0.2ft Step 7: Install Software NEC Express5800/ft Series offers Step 8: Connect and Configure Options Step 9: Set Network for NEC ESMPRO Agent...
Follow the procedure below to install ESX Server. IMPORTANT: NEC Express5800/ft series is a precision equipment. It is recommended to ask engineer from maintenance service provider with good knowledge for setup. Operate the step 1 to 11. Step 1: Start setup procedure for installing ESX Server The followings are required for the ESX Server installation.
Before installing ESX Server, be sure to do the following. If you do not prepare, setup cannot be performed properly. Prepare NEC Express5800/ft series With the power of NEC Express5800/ft series off, follow the steps below: Prepare NEC Express5800/ft series. Follow the instructions below to prepare.
Page 65
Execute the operation to be taken when AC power supply is turned off. <When the AC power is off (The power cord is not plugged into the outlet)> Connect the power cords to NEC Express5800/ft series in the following order: Connect the power cord to the AC inlet A connector.
4-6 ESX Server Setup Step 3: Validate FC card Turn on the display and the peripheral equipment connected to the NEC Express5800/ft series. CHECK: If the power cords are connected to a power controller like a UPS, make sure that it is powered on.
Page 67
ESX Server Setup 4-7 When the message “Press <F2> to enter SETUP” or “Press <F2> to enter SETUP or Press <F12> to boot from Network” is displayed on the display screen, press F2. The BIOS Setup Utility “SETUP” starts and the Main menu is displayed on the screen. <Example>...
Page 68
4-8 ESX Server Setup Move the cursor onto [Advanced] and select [Advanced]. The Advanced menu appears. Move the cursor onto [Option ROM Configuration] and press Enter. The Option ROM Configuration submenu appears.
Page 69
ESX Server Setup 4-9 Move the cursor onto [PCI Slot3 (upper) Option ROM] and press Enter. Parameters appear. Among the parameters, choose [Enabled] and press Enter. The current display of the configuration for PCI Slot3 (upper) Option ROM will be changed to [Enabled.]...
Page 70
4-10 ESX Server Setup Move the cursor onto [Embedded SAS Option ROM] and press Enter. Parameters appear.
Page 71
ESX Server Setup 4-11 Select [Disabled] from the parameter and press Enter. The display of current configuration for [Embedded SAS Option ROM] becomes [Disabled.]. This is the end of steps for validating FC card. . The following procedure shows how to invalidate the monitoring function. Process “Step 4: Invalidate OS Boot Monitoring function”...
Configure this to confirm the power is on and to process appropriately the setup later The NEC Express5800/ft series has a monitoring function at start up. Invalidate the monitoring function when installing. If you do not invalidate the function, you will not be able to complete the installation correctly.
Page 73
ESX Server Setup 4-13 Move the cursor onto [Monitoring Configuration] and press Enter. The Monitoring Configuration submenu appears. Move the cursor onto [OS Boot Monitoring] and press Enter. Parameter appears.
Page 74
4-14 ESX Server Setup Select [Disabled] from the parameter and press Enter. The display of current setting for OS Boot Monitoring becomes [Disabled]. Press Esc key, then go back to Server menu, and move the cursor onto [Exit]. The Exit menu appears.
Page 75
ESX Server Setup 4-15 Move the cursor key onto [Exit Saving Changes] and Press Enter. The Setup confirmation window appears. Select [Yes] and press Enter. Save the setting and quit the SETUP, and then reboot. TIPS: When installing ESX Server, once power off the server for preparation of installation. Then go on setup to the next page “Step 5 Set HBA configuration by Emulex BIOS”...
4-16 ESX Server Setup Step 5: Set HBA configuration by Emulex BIOS IMPORTANT: Before configuring the settings for HBA by Emulex BIOS, it is required to complete the storage settings such as creating a logical disk. Start from the CPU/IO module 0 and perform the following. Start the configuration window of Emulex BIOS.
Page 77
ESX Server Setup 4-17 Select [Enable or Disable BIOS]. Select 1 so that [Enabled] is configured.
Page 78
4-18 ESX Server Setup Select Esc twice to return to the screen where FC card has been selected. Select [Configure Boot Devices].
Page 79
ESX Server Setup 4-19 Select the location for Boot Entry (select 1). Select the boot device (select 01).
Page 80
4-20 ESX Server Setup 1.10 Enter LUN (Hex) (select 00). 1.11 Select Boot LUN (select 01).
Page 81
ESX Server Setup 4-21 Select “WWPN”. 1.12 1.13 Select x and then Y, then reboot the OS. Start from the CPU/IO module 1. Perform steps 1.1 to 1.13 similarly. CHECK: The images shown in 1.9-1.11 are examples. The information displayed varies depending on the product name of external storage and settings (e.g.
4-22 ESX Server Setup Step 6: Install VMware ESX Server 3.0.2ft Insert the install CD of ft control software for VMware Infrastructure to start the machine. The ftSys logo is displayed. IMPORTANT: Set CPU/IO module 0 as the primary, and insert the installation CD into the drive of primary side.
Page 83
ESX Server Setup 4-23 After confirming the agreement in the [End User License Agreement] window, tick the checkbox of [I accept the terms of the license agreement] and click [Next]. If the [Warning] shown in the right appears, click [Yes]. Initialization of the partition table is performed.
Page 84
4-24 ESX Server Setup Change the partition configuration and size in the Partition Disks window. Select the recommended settings in principle. If you change the partition size, do not configure the smaller size than the recommended value. Save about 2GB disk space for the partition that includes /var/crash because the dump file is stored under /var/crash when collecting the...
Page 85
ESX Server Setup 4-25 Select a region in Time Zone Selection. Untick the checkbox of [System clock UTC] to select a country. Do not untick if using UTC. Click [Next]. In Set Root Password, enter the password for Root account and click [Next].
4-26 ESX Server Setup Step 7: Install Software NEC Express5800/ft Series offers Install the software provided by NEC Express5800/ft series by the following procedures. ft Server Control Software Select [VMware ESX Server] in the bootloader (Grub) window and press Enter. When starting ESX Server completes, [VMware ESX Server version 3.0.2ft] is displayed.
# cd /(mount point)/smm_drv/vmware_3.0.2/320Fd/ # rpm –ivh *.rpm Move to the directory where the package of the NEC ESMPRO Agent is stored and run the rpm command to install. # cd /(mount point)/esmpro_sa/4361-01/ # rpm -ivh Esmpro-common-*...
Step 8: Connect and Configure Options If there is any optional PCI board or peripheral equipment to connect to NEC Express5800/ft series, turn off the power to NEC Express5800/ft series, and connect it according to the “PCI board” in User’s Guide and the device’s instruction.
ESX Server Setup 4-29 Step 9: Set Network for NEC ESMPRO Agent NEC ESMPRO Agent is required for continuous operation of the NEC Express5800/ft series. To run NEC ESMPRO Agent, you need to configure the SNMP settings. For details and methods of the settings, refer to “Installing Management Utility.”...
4-30 ESX Server Setup Step 10: Enable OS Boot Monitoring Function When necessary for system operation, enable the [OS Boot Monitoring] setting which has been disabled in “Step 3: Validate FC card” (page 4-6). Set appropriate time referring to “Step 3: Validate FC card” (Default is 10 minutes. Specify by second).
Follow the steps below to make a backup copy of the system information: Prepare a 3.5-inch floppy disk. Insert the NEC EXPRESSBUILDER DVD into the optical disk drive and reboot the system. NEC EXPRESSBUILDER is activated and [Boot selection] menu is displayed. Select [Tool menu] Select [English].
4-32 ESX Server Setup Setup Procedures upon Installing Guest OS For the setup procedures upon installing guest OS, see Guest Operating System Installation Guide of VMware Infrastructure. For the network configuration, refer to the User’s Guide packaged with this guide and the Server Configuration Guide of VMware Infrastructure. NOTE: It is not recommended that guest OS uses the optical disk drive on the ESX host during operation.
Chapter 5 Procedures after Completion of Installation This chapter describes the procedures after installation such as how to install management utilities and how to setup PCs on the network. You may need to confirm these procedures while the system is running.
The provided "NEC EXPRESSBUILDER" CD-ROM contains "NEC ESMPRO Agent" for monitoring NEC Express5800/ft series and "NEC ESMPRO Manager" for managing the NEC Express5800/ft series. Install and setup these management utilities in the NEC Express5800/ft series or the computer (management PC) that manages the NEC Express5800/ft series.
Installation Guide included in the CD-ROM of “NEC ESMPRO Agent for VMware Infrastructure 3”. In order for NEC ESMPRO Agent to operate, it is necessary to configure the settings according to your environment. See the User’s Guide included in the CD-ROM of “NEC ESMPRO Agent for VMware Infrastructure 3”.
2. SNMP service settings To monitor from NEC ESMPRO Manager, it is necessary to change SNMP environment setting file (/etc/snmp/snmpd.conf) to set a community right to more than “READ WRITE”. Refer to the following to modify the environment setting file by vi command etc.
Page 97
# /sbin/chkconfig --level 345 portmap on 5. Setting firewall When monitoring the device where NEC ESMPRO Agent is installed from the NEC ESMPRO Manager, use the following port. If you set the firewall on your environment, set the access permission to the following ports.
3. Move to the directory where the server management driver is stored, and install by the rpm command. # cd /(mount point)/smm_drv/vmware_3.0.2/320Fd/ # rpm –ivh *.rpm 4. Move to the directory where the package of the NEC ESMPRO Agent is stored, and install by the rpm command. # cd /(mount point)/esmpro_sa/4361-01/ # rpm -ivh Esmpro-common-*...
Procedures after Completion of Installation 5-7 Uninstallation procedure 1. Log in to the service console as a root user. 2. Run the following command to uninstall the package. Note that procedures vary depending on the server you use. # rpm -e Esmpro-Express # rpm -e Esmpro-ft # rpm -e Esmpro-type1 # rpm -e Esmpro-common...
Notify Monitor When a failing module in the server is to be replaced, NEC ESMPRO Manager enables logical module disconnection from the server and logical installation after module replacement. For the installation of NEC ESMPRO Manager and notes on the operation, see the separate volume...
Page 101
Copy the following file in the “ft control software for VMware Infrastructure installation CD” and copy it to an arbitrary directory. \NEC\LANG\EN\PROG\FTREG.EXE Run Command prompt and type the directory where you copied the above file, then enter the following command.
Page 102
5-10 Procedures after Completion of Installation This setting program is to configure the following registry of Windows. Windows XP/Windows NT/Windows 2000/Windows Server 2003 Registry key: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters Value: TcpMaxConnectRetransmissions Type: REG_DWORD Configuration value: 5 Value: TcpMaxDataRetransmissions Type: REG_DWORD Configuration value: 8 Value: TcpMaxConnectREsponseRetransmissions Type: REG_DWORD Configuration value: 5...
Page 103
Procedures after Completion of Installation 5-11 Disable Auto Reinstallation of CPU Module You can disable the auto reinstallation of CPU module with the following configuration. You can shift the timing of no communication that occurs during the installation process of CPU module by disabling the auto reinstallation of CPU module and manually enabling the installation of the module.
Page 104
5-12 Procedures after Completion of Installation Manually install CPU module Confirm which CPU/IO module is the primary. CPU/IO module 0 is the primary – Path of CPU module to be installed is 1. CPU/IO module 1 is the primary – Path of CPU module to be installed is 0. Install CPU module (Run the following command depending on the status of CPU/IO module) - CPU/IO module 0 is the primary...
Page 105
Procedures after Completion of Installation 5-13 You can also limit the auto reinstallation of CPU timing by combination with cron daemon. 1. Add configuration to /etc/crontab Example: Disable auto reinstallation of CPU module from 6:00 to 18:15 everyday. Add the following rows to /etc/crontab # Defer CPU bringup at 6:00 every day # Enable CPU bringup at 18:15 every day 0 6 * * * root /opt/ft/bin/ftsmaint bringupPolicy defer...
5-14 Procedures after Completion of Installation Confirmation of the Kernel Version The following describes how to check the version of ESX Server and the version of the kernel in the service console. Check the version following the steps below. ESX Server Run the following command on the service console.
The following describes how to check the version of ft Server Control Software. Perform the procedure when you need to check the ft Server Control Software version of the current system such as before adding units or attachment to NEC Express5800/ft series. Confirm the version following the steps below: 1.
Page 108
5-16 Procedures after Completion of Installation (This page is intentionally left blank.)
6-2 Troubleshooting SYSTEM REPAIR For repairing the service console, try fsck. IMPORTANT: If the sd device cannot be recognized by the service console, the system cannot be repaired. To execute this configuration, login as a user with root privilege. # fsck -C -pvf /dev/sd* *:device ID Try the guest OS repairing method according to each OS.
Did you set the NEC EXPRESSBUILDER DVD during POST and restart the server? If you do not set the NEC EXPRESSBUILDER DVD during POST and restart the server, an error message will appear or the OS will boot.
Page 112
6-4 Troubleshooting (This page is intentionally left blank.)
Appendix A About Services Information on NEC Express5800/ft series is provided the web at NEC Express5800 Web ASIA PACIFIC http://www.nec.co.jp/express/...
Page 116
N8800-128F, EXP320J NEC Express5800/320Fd-LR N8800-129F, EXP320K NEC Express5800/320Fd-MR User's Guide (Setup) 2nd Edition 9-2008 856-127506-112- B...