Oscillator Control Register (Osccon) - Samsung S3C8275X User Manual

8-bit cmos microcontrollers
Table of Contents

Advertisement

CLOCK CIRCUIT

OSCILLATOR CONTROL REGISTER (OSCCON)

The oscillator control register, OSCCON, is located in set 1, bank 0, at address E0H. It is read/write addressable
and has the following functions:
System clock selection
Main oscillator control
Sub oscillator control
Sub oscillator circuit selection
OSCCON.0 register settings select Main clock or Sub clock as system clock.
After a reset, Main clock is selected for system clock because the reset value of OSCCON.0 is "0".
The main oscillator can be stopped or run by setting OSCCON.3.
The sub oscillator can be stopped or run by setting OSCCON.2.
Sub oscillator circuit selection bit:
0 = Initial state
1 = Power saving circuit for sub oscillator
(Automatically cleared to "0" when the sub
oscillator is stopped by OSCCON.2)
NOTES:
1. The OSCCON.7 must be maintained to "1", during
the suboscillator operation.
2. A capacitor (0.1uF) should be connected between
VREG and GND.
7-6
Oscillator Control Register (OSCCON)
E0H, Set 1, Bank 0, R/W
MSB
.7
.6
.5
Not used for S3C8275X/
C8278X/C8274X
Main oscillator control bit:
0 = Main oscillator RUN
1 = Main oscillator STOP
Figure 7-10. Oscillator Control Register (OSCCON)
S3C8275X/F8275X/C8278X/F8278X/C8274X/F8274X
.4
.3
.2
.1
System clock selection bit:
0 = Main oscillator select
1 = Sub oscillator select
Not used for S3C8275X/C8278X/C8274X
Sub oscillator control bit:
0 = Sub oscillator RUN
1 = Sub oscillator STOP
.0
LSB

Advertisement

Table of Contents
loading

This manual is also suitable for:

F8275xF8274xC8278xC8274xF8278x

Table of Contents