Sharp JW-20FL5 User Manual page 117

Fl-net module (board)
Table of Contents

Advertisement

Chapter 9: Message transfers
Monitor PC operation status (COM = E8
[Format]
Ë Command
COM MODE
Ë Response
COM
RSLT MODE
COM
MODE
[Function]
- Monitor PC run/stop status.
[Execution condition]
- Write enable mode
- PC operation status
[Example]
- Monitor PC operation status.
Ë Command
E8
Ë Response
9
E8
= E8
(H)
= 00
: Operating
(H)
01
: Stopped operation by an instruction from other module.
(H)
02
: Stopped operation by an instruction from this module.
(H)
: Mode 0, mode 1 and mode 2
: Stopping, operating
00
00
Operating
)
(H)
9-40