Ventilation System
DA 249-4
en - US, CA
To prevent accidents
and appliance damage,
read these instructions
before
installation or use.
M.-Nr. 07 781 040

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA 249-4

  • Page 1 Operating and Installation Instructions Ventilation System DA 249-4 en - US, CA To prevent accidents and appliance damage, read these instructions before installation or use. M.-Nr. 07 781 040...
  • Page 2: Table Of Contents

    Contents IMPORTANT SAFETY INSTRUCTIONS....... . . 3 Functional description ..........7 Guide to the Ventilation System .
  • Page 3: Important Safety Instructions

    Use this appliance only in the manner intended by the manufacturer. Read these instructions carefully If you have questions, contact Miele. before installing or using the b) Before servicing or cleaning the Ventilation System. appliance, switch power off at the...
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS d) Before connecting the appliance to the power supply make sure that the ,WARNING voltage and frequency listed on the data plate correspond with the TO REDUCE THE RISK OF A household electrical supply. COOKTOP GREASE FIRE: This data must correspond to prevent appliance damage.
  • Page 5 IMPORTANT SAFETY INSTRUCTIONS ,WARNING Do not allow children to play with or operate the appliance or its controls. TO REDUCE THE RISK OF Supervise its use by the elderly or INJURY TO PERSONS IN THE infirm. EVENT OF A COOKTOP Always turn on the hood when using GREASE FIRE, OBSERVE THE the cooktop to prevent damage from...
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS Installation g) Do not install this hood over cooktops that burn solid fuel. ,WARNING h) Provided a larger distance is not TO REDUCE THE RISK OF given by the manufacturer of the FIRE, ELECTRIC SHOCK, OR cooktop, follow the minimum safety distances between a cooktop and the INJURY TO PERSONS, bottom of the hood given in the...
  • Page 7: Functional Description

    Functional description The hood offers two modes of operation: Air extraction Recirculation mode The air is drawn in and cleaned by the Air is drawn through the decor panel, decor panel and the grease filter and grease filter and an active charcoal directed outside.
  • Page 8: Guide To The Ventilation System

    Guide to the Ventilation System...
  • Page 9: Guide To The Ventilation System

    Guide to the Ventilation System Chimney extension Grease filter button The indicator next to the grease filter Recirculation vent button lights when the grease filter and decor cover need to be cleaned. This For recirculation use with optional button is also used: accessories –...
  • Page 10: Operation

    Operation Turning on the fan Automatically switching back the Intensive power level The intensive level "4" can be programmed to automatically switch back to level "3" after 10 minutes. ^ Press the On/Off button. ^ Turn the fan and the lights off. The fan runs at power level "2".
  • Page 11 Operation Fan performance The maximum air flow capacity is 625 cfm. Factors such as narrow duct diameter and bends will affect this If the power level indicators "1" and "4" value. flash, the automatic switch back is not Level 1 operates at 40% capacity activated.
  • Page 12: Delayed Shut Down

    Operation Delayed Shut Down Turning off the fan If odors or smoke remain in the kitchen after cooking has been completed, the Delayed Shut Down feature can be selected to allow the hood to continue ^ Press the On/Off button to turn the running for either 5 or 15 minutes.
  • Page 13: Turning The Lighting On/Off

    Operation Turning the lighting on/off Dimming the lighting The overhead lighting can be turned The brightness of the lighting can be on and off independently of the fan. adjusted. ^ While the lighting is turned on, press the light button. The lighting will dim until the button is released.
  • Page 14: Filter Timers

    Operation Filter timers Checking the filter timers To check the percentage of time Grease filter already used: A timer monitors the hours of fan operation. The indicator for the grease filter will light after 30 hours of operation. The grease filter must then be cleaned.
  • Page 15: Reprogramming The Timers

    Operation Reprogramming the timers The grease filter timer is preset to 30 hours. This time can be lengthened or shortened to 20, 30, 40 or 50 hours. The indicator for the grease filter and – A time of 20 hours should be one of the "–/+"...
  • Page 16 Operation Reprogramming the charcoal filter timer The active charcoal filter can only be used in recirculation mode and can not The indicator for the charcoal filter and be used to exhaust fumes. one of the "–/+" indicators will flash. The charcoal filter timer is not preset. The lit indicator shows the programmed Before using the hood in recirculation time:...
  • Page 17: Cleaning And Care

    Cleaning and Care ,WARNING Avoid: TO REDUCE THE RISK OF – cleaning agents containing soda, FIRE, ELECTRIC SHOCK, OR acids, solvents or chlorides, INJURY TO PERSONS, – abrasive cleaning agents OBSERVE THE FOLLOWING: e.g. powder or cream cleansers, – abrasive sponges, e.g. pot scourers Before cleaning or servicing the or sponges which have been hood, disconnect it from the power...
  • Page 18: Grease Filter

    Cleaning and Care Grease filter Removing the decor cover The decor panel and reusable metal grease filter remove solid particles from the vented kitchen air (grease, dust, etc). The grease filter is visible when the decor cover is removed. The grease filters should be cleaned every 3 - 4 weeks, when the grease ^ To remove the decor cover, pull on filter indicator lights, or when they are...
  • Page 19 Use a wash program with a max. temperature of 150°F (65°C). In a Miele dishwasher use the "Normal" program. Use the recommended amount of dishwasher detergent. Overuse could destroy the filter.
  • Page 20: Active Charcoal Filters

    The charcoal filter is designed to absorb cooking odors. Replacement active charcoal filters can be ordered from Miele. ^ The decor cover must be removed to access the active charcoal filter. See ^ To remove the active charcoal filter "Cleaning and Care".
  • Page 21 Cleaning and Care Replace the active charcoal filter when the charcoal filter indicator lights. Replace the filter at least every 6 months or when it no longer absorbs odors efficiently. The old charcoal filter can be disposed of in the household waste. ^ After replacing the charcoal filters, press and hold the charcoal filter button for about 3 seconds to reset...
  • Page 22: Changing The Light Bulbs

    Cleaning and Care ^ Remove the decor cover, see Changing the light bulbs "Cleaning and Care / Removing the ,WARNING decor cover". TO REDUCE THE RISK OF ^ Pull the old bulb out of its socket and FIRE, ELECTRIC SHOCK, OR replace it with a new one of the same type.
  • Page 23: After Sales Service

    Miele’s Service department, Extended Service Contracts offered by other providers for Miele products will not be recognized by Miele. Our goal is to prevent unauthorized (and untrained) service personnel from working on your Miele products, possibly doing further damage to them, you and/or your home.
  • Page 25: Installation Instructions

    Installation Instructions Read these instructions and the "Important Safety Instructions" before installing this ventilation system. The installation steps are described in the enclosed "Installation Diagram". Leave these instructions with the appliance for the consumer/user. Information is subject to change. Please refer to our website to obtain the most current product specification, technical &...
  • Page 27: Caring For The Environment

    Caring for the environment Disposal of packing material Disposal of an old appliance The cardboard box and packing Old appliances may contain materials materials protect the appliance during that can be recycled. Please contact shipping. They have been designed to your local recycling center about the be biodegradable and recyclable.
  • Page 28: Appliance Dimensions

    Appliance dimensions...
  • Page 29: Appliance Dimensions

    If the standard unit height H is not outlet installation are necessary. suitable to the kitchen’s ceiling height, longer optional chimney extensions are available from your Miele dealer or The installation procedure differs Miele. depending on the model and venting method.
  • Page 30 Do not install this exhaust hood over cooktops burning solid fuel. Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood: Miele Cooktops Non-Miele Cooktops Electric Cooktops 24"...
  • Page 31: Plywood Backing

    Plywood backing ^ Find the studs to the left and right of The majority of the weight of the the mounting location by tapping the installed ventilation system will be wall or using a stud finder. supported by the lower retaining ^ Mark a vertical cutting line along the plate.
  • Page 32: Installation

    Installation...
  • Page 33 Installation 2 protective shields prevent scratches to the chimney during installation. 8 large headed screws 5 x 40 mm 1 vent collar for securing the retaining plates and the for use with 6" (150 mm) exhaust canopy. ducting (S8 wall anchors included in the 1 reducing collar packaging are not for use in USA / CDN.) for use with 5"...
  • Page 34: Installation

    Installation Protective film Dismantling The casing is covered with a protective If the hood needs to be disassembled, film to prevent scratching during follow the instructions on the transport. "Installation diagram" in the reverse order. ^ Peel off the film before installing the casing parts.
  • Page 35: Air Extraction

    Air extraction Exhaust ducting and connections WARNING Use smooth or flexible pipework made from approved non-flammable Danger of toxic fumes. materials for exhaust ducting. Gas cooking appliances release To achieve the most efficient air extraction and quietest noise levels, carbon monoxide that can be consider the following: harmful or fatal if inhaled.
  • Page 36: Condensate Trap

    Air extraction Condensate trap optional accessory – If the exhaust is ducted into an inactive flue, the air must be expelled In some cases, a condensate trap may parallel to the flow direction of the also be required to collect and flue.
  • Page 37: Electrical Connection

    If there is any question concerning the electrical connection of this appliance to your power supply, please consult a licensed electrician or call Miele’s Technical Service Department. ,WARNING: THIS APPLIANCE MUST BE GROUNDED...
  • Page 38: Technical Data

    Technical data Maximum load ....390 W Lighting ....2 x 20 W Voltage .
  • Page 40 Alteration rights reserved / 2011 M.-Nr. 07 781 040 / 02 INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION.