Function Mode - Hitachi L700 SERIES Instruction Manual

L700 series
Hide thumbs Also See for L700 SERIES:
Table of Contents

Advertisement

Chapter 8 List of Data Settings
Code
Function name
d025
User monitor 0
d026
User monitor 1
d027
User monitor 2
d028
Pulse counter
d080
Trip Counter
d081
Trip monitoring 1
d082
Trip monitoring 2
d083
Trip monitoring 3
d084
Trip monitoring 4
d085
Trip monitoring 5
d086
Trip monitoring 6
d090
Programming error monitoring
d102
DC voltage monitoring
d103
BRD load factor monitoring
Electronic
thermal
d104
monitoring

8.3 Function Mode

Code
Function name
F001
Output frequency setting
F002
Acceleration (1) time setting
F202
Acceleration (1) time setting,
2nd motor
F302
Acceleration (1) time setting,
3rd motor
F003
Deceleration (1) time setting
F203
Deceleration time setting,
2nd motor
F303
Deceleration time setting,
3rd motor
F004
Keypad Run key routing
Monitored data or setting
-2147483647 to 2147483647 (upper 4 digits including "-")
-2147483647 to 2147483647 (upper 4 digits including "-")
-2147483647 to 2147483647 (upper 4 digits including "-")
0 to 2147483647 (upper 4 digits)
0. to 9999., 1000 to 6553 (10000 to 65530) (times)
Factor, frequency (Hz), current (A), voltage across P-N (V),
running time (hours), power-on time (hours)
Factor, frequency (Hz), current (A), voltage across P-N (V),
running time (hours), power-on time (hours)
Factor, frequency (Hz), current (A), voltage across P-N (V),
running time (hours), power-on time (hours)
Factor, frequency (Hz), current (A), voltage across P-N (V),
running time (hours), power-on time (hours)
Factor, frequency (Hz), current (A), voltage across P-N (V),
running time (hours), power-on time (hours)
Factor, frequency (Hz), current (A), voltage across P-N (V),
running time (hours), power-on time (hours)
Warning code
0.0 to 999.9 (V)
0.0 to 100.0 (%)
overload
0.0 to 100.0 (%)
0.0, "start frequency" to "maximum frequency"
(or maximum frequency, 2nd/3rd motors) (Hz)
0.0 to 100.0 (when PID function is enabled)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
00 (forward rotation), 01 (reverse rotation)
Monitored data or setting
8 - 2
Setting
Change
during
during
Default
operation
operation
(allowed or
(allowed or
not)
not)
Setting
Change
Default
during
during
operation
operation
(allowed or
(allowed or
_FF
not)
not)
0.00
30.00
30.00
30.00
30.00
30.00
30.00
00
Page
4-5
4-5
4-5
4-5
4-5
4-5
4-6
4-6
Page
4-7
4-10
4-10
4-10
4-10
4-10
4-10
4-7

Hide quick links:

Advertisement

Table of Contents
loading