INSTALLATION INSTRUCTIONS
PLEASE READ AND SAVE THESE INSTALLATION INSTRUCTIONS.
P/NO.: MFL06208702
Printed in Korea

Advertisement

Table of Contents
loading

Summary of Contents for LG LMVM2277ST

  • Page 1 http://us.lgservice.com IORO INSTALLATION INSTRUCTIONS PLEASE READ AND SAVE THESE INSTALLATION INSTRUCTIONS. P/NO.: MFL06208702 Printed in Korea...
  • Page 2: Your Safety First

    YOUR SAFETY FIRST BEFORE YOU START • Proper installation is the installer's responsibility! - Read the entire manual before you begin. - The Model number label is located on the front of oven, behind door. See Figure 1. - Mounting plate is located on back side of microwave oven.
  • Page 3 YOUR SAFETY FIRST • THIS APPLIANCE MUST BE GROUNDED! If there is an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug.
  • Page 4 YOUR SAFETY FIRST • MAKE SURE YOU HAVE ENOUGH SPACE AND SUPPORT. - Mount the oven against a flat, vertical wall, so that it is supported by the wall. The wall should be constructed of minimum 2" x 4" wood studding and 3/8" thick drywall or plaster/lath. - ATTACH AT LEAST ONE of the two lag screws supporting the oven to a vertical, 2"...
  • Page 5: Parts, Tools, Materials

    PARTS, TOOLS, MATERIALS THE FOLLOWING PARTS ARE SUPPLIED WITH THE OVEN: NOTE: Depending on your ventilation requirements, you may not use all of these parts. Damper/duct connector power cord clamp and (for roof venting or wall venting installation) One dark-colored mounting screw_ Not Actual Size (2 pieces must be assembled as (to hold the power cord)
  • Page 6 PARTS, TOOLS, MATERIALS You will need the following tools and materials for the installation: Carton or other heavy material for covering the counter top. Clear Tape Stud Finder (for taping the templates to the wall) Keyhole Saw (for the power cord hole) (for cutting vent holes for roof or wall venting) Saber Saw...
  • Page 7 STEP 1: PREPARE THE ELECTRICAL CONNECTIONS WARNING AVOID ELECTRICAL SHOCKt THiS APPLIANCE MUST BE GROUNDED! 1. Locate the grounded electric outlet for this oven in the cabinet above the oven, as shown in Figure 5. Upper NOTE: The outlet should be on a circuit dedicated to the microwave oven (120V, 60 Hz., AC only) with a 15 or 20A fused electrical supply.
  • Page 8: Step 2: Prepare The Venting System

    STEP 2: PREPARE THE VENTING SYSTEM NOTE: The ductwork you need for outside ventilation is not included with your oven. The standard ductwork fittings and length are shown in Figure 10, page 9. WARNING THIS OVEN MUST BE PROPERLY VENTED! You may vent your oven in one of three ways.
  • Page 9 Standard Fittings NOTE: If the existing duct is round, you must use a rectangular-to-round adapter, with a rectangular 3" extension duct installed between the damper assembly and the adapter to prevent the exhaust damper's sticking. Duct Length The total length of the duct system, including straight duct, elbows, transitions, and wall or roof caps must not exceed the equivalent of 140 feet.
  • Page 10 STEP 3: PREPARE THE VENTING BLOWER WARNING + To avoid risk of property damage, unplug the microwave oven or disconnect power at source by removing fuse or throwing circuit breaker. +To avoid risk of personal injury, wear protective gloves when handling mounting plate.
  • Page 11 3.Reassemble theblower wire. S eeFigure 1 4. 4.Rotate t heunit s othat t heexhaust ports face therear o fthecabinet. SeeFigure 1 6. W hen youinsert blower unit, blower wire must belike figure 15. 5.Place b lower unit b ack into cabinet. Check t hat t heexhaust ports f ace towards therear o fthecabinet. See Figure 6.Reattach theblower plate tocabinet sotheexhaust ports andblower plate opening arealigned.
  • Page 12: Step 4: Prepare The Wall & Upper Cabinet

    STEP 4: PREPARE THE WALL & UPPER CABINET WARNING To avoid personal injury or property damage, do not attempt to install this microwave oven if you cannot find a wall stud, Measure And Tack/Tape Up The Templates 1. Using a plumb line and measuring tape, find and mark the vertical center line on the back wall, as in Figure 23.
  • Page 13 WARNING To avoid risk of personal injury, electrical shock or death: o Note where electrical outlets and electrical wires are before you drill into the wall. • Locate and disconnect power to any electrical circuits that could be affected installing this oven.
  • Page 14 STEP 5: INSTALL THE MOUNTING PLATE The Oven Must Be Connected To At Least One 3/16 Hole on Studs 5/8 Hole on Dry wall Only Wall Stud. From the Floor 1. Draw a vertical line on the wall at the center of the 30 wide space.
  • Page 15 For Wall-Vented • Make the box cutout for the rear wall duct. Use the wall template to determine the location and size of the box cutout for the rear wall duct. • Attach the exhaust adapter to the rear plate. See Figure 30. Push in securely until it is past the top locking tabs and in the lower locking tabs.
  • Page 16: Step 6: Attach The Oven To The Wall

    STEP 6: ATTACH THE OVEN TO THE WALL WARNING To avoid risk of personal injury or property damage, use will need two people to install this microwave oven. power cord 1. Carefully lift microwave oven and hang it on support tabs hole (See Figure 27) at the bottom of the mounting plate.
  • Page 17 STEP 6: ATTACH THE OVEN TO THE WALL 5. Roof venting installation: See Figure 33. Install ductwork through the vent opening in the upper cabinet. Complete the venting system through the damper roof according to the method needed. See "Prepare The Venting System"...