Chapter 2 Message List
iSM03224: Control path is blockaded.
[Classification
[Explanation]
[Measures]
iSM03225: Data can not be gotten sequentially
[Classification]
[Explanation]
[Measures]
ip=(<aaa...a>) func=<bbb...b>
errno=<ccccc> status=<ddddd>
(<eee...e> productID=<fffff>
SN=<ggggg>) [UC=<hhhhhhhh>
FC=<ii>]
ERROR
The control path (SVP access) was blockaded.
aaa...a
: IP address
bbb...b
: Function number
ccccc
: Error number
ddddd
: Result of issuing of SCSI command
eee...e
: Disk array name
fffff
: Product ID of disk array (for example, S2100 Disk Array etc.)
ggggg
: Serial number of disk array
hhhhhhhh/ii : Maintenance information
Check the status of the disk array, and remove the cause of failure.
during split mode.Disk=(disk<aaa>
(Port<bbb> Bus<ccc> Target<ddd>
Lun<eee>)) reason=(invalid
sequence) detail=<ff-gggg>
ERROR
Obtaining data failed in command divided transfer.
that retry processing could not obtain correct data either.
diskaaa (Portbbb Busccc Targetddd Luneee): Disk information
ff-gggg
: Detail information (This code isn't disorder reason but a value
for maintenance.)
Check the status of the disk array, and remove the cause of failure. If necessary,
restart monitoring manually.
52
The message indicates