49. Gently open the flex connector. Avoid putting pressure to
the components.
51....continue at the large connector.
53. Keep this adhesive clean if this part should be reused.
Remove any adhesive residues on the opposing part.
55. Now the CAMERA FLEX MODULE can be removed together
with the CAMERA MODULE.
Page
6
(25)
CONFIDENTIAL
Copyright © 2007 NOKIA. All rights reserved.
50. Lift up the glued inTOP FLEX , beginning at the shown side...
52. If all adhesive parts are released, the Top FLEX ASSY can be
removed easily.
54. Open the flex connector of the CAMERA FLEX MODULE.
56. Slightly bend the D-COVER in order to release the clip. Do not
touch the components or the spring contact.