Download Print this page

Verifying Proper Operation; Additional Information - HP StorageWorks P2000 - G3 MSA Array Systems Installation Instructions

Hp storageworks controller module installation instructions (590339-003, february 2010)
Hide thumbs Also See for StorageWorks P2000 - G3 MSA Array Systems:

Advertisement

Verifying proper operation

Examine module status as indicated in
If the Fault LED is amber, the module has not gone online and likely
failed its self-test. Remove and reinstall the module.
Table 1 LED descriptions
Module LED
Description
OK
Fault/Service Required
Verifying the firmware version
After replacing a controller, verify that the latest firmware is installed on
all controllers in the controller enclosure. Go to the website for your
enclosure model and, if newer firmware is available, download the
firmware from the Web and install this latest version on the controller(s).
For more information on firmware updates, see the storage enclosure
user guide.
Upgrading from single-controllers to
dual-controllers
As appropriate for your environment, connect cables from this new
module to the host or other disk enclosures. For more information about
cabling and configuring the system, see the user guide.

Additional information

HP StorageWorks Modular Smart Arrays:
HP storage:
http://www.hp.com/storage
HP support:
http://www.hp.com/support
HP documents:
http://www.hp.com/support/manuals
Table
1.
Solid Green = Module is operating
normally
Blink = System is starting up
Off = Module is NOT operating nor-
mally
Solid Amber = Fault condition
Blinking Amber = Hardware-controlled
power-up or cache flush/restore error
Off = No fault conditions
http://www.hp.com/go/msa
Page 3

Advertisement

loading