MINIMUM
COPPER
WIRE SIZE
(AWG)
FIGURE 1
Typical Wiring Diagrams—SPDT
TO POWER SUPPLY
TO POWER SUPPLY 1
OPERATING INSTRUCTIONS
BASIC SETTINGS:
Initial Set Up:
1. Push the "R" button before programming to clear out any settings. Once
the "R" button is pressed the screen will begin to flash. A paperclip may
be needed for this step.
(If the "R" button appears to stick down, use a toothpick to maneuver
it until it pops back up. The screen will flash if the button is popped up
successfully.)
2. Press the "Clock" button and the screen will stop flashing and be ready
for programming.
Setting the Current Time:
1. Press and Hold the "Clock" button during the entire setting.
2. Press the "H+" button to set the hours.
3. Press the "M+" button to set the minutes.
4. Press the "Day" button to set the day of the week.
5. Release the "Clock" button.
Programming ON/OFF Settings:
1. Press the "Timer" button once and the TIMER 1 ON - - : - - appears.
2. Press the "H+" and "M+" button to set the hours and minutes to the
desired time.
3. Press the "Day" button to select the day(s) the setting will be active. Refer
to the Multiple Weekday Group below to see the available settings.
4. Press the "Timer" button to store the setting and proceed to the next
setting TIMER 1 OFF - - : - -.
5. Repeat for all remaining setting options (9 Total ON/OFF settings). Once
completed press the "Clock" button to return to the main display.
75°C INSULATION MAX. MOTOR
MAX.
MIN.
LOAD (HP)
INSUL-
LOAD
ATION
(AMP)
SINGLE PHASE
TEMP(°C)
120 V.
240 V.
14
15
60
1/2
2
2 1/2
12
20
60
1
10
3
30
60
2
8
105
-
5
40
Timer and Load, Same Voltage
Wired as Single Throw
T
TIMERN
NC
OC OM
TO LOAD
Timer and Load, Different Voltage
Wired as Single Throw
T
TIMERN
CN OC OM
TO POWER SUPPLY 2
LOAD
120V Two Speed Fan
Wired as Double Throw
T
TIMERN
CN OC OM
H
HIGH
TO 120V LINE
LOW
COM
N
Field Wiring
Timer Inter n ab Wiring
3 PHASE
208 V.
240 V.
N/A
N/A
Typical Wiring Diagrams—DPDT
120V Timer, 200/240/277V Load Double Break
T
TIMERN
H
TO 120V LINE
N
120V Timer, 120V Load and 24V Load
T
TIMERN
H
TO 120V LINE
N
N
TO LOAD
H
200/240/277V Timer, 200/240/277V Load, Double Break
T
TIMERN
L1
L2
R
(Reset)
H-
(Hours Setting)
M-
(Minutes Setting)
Day
(Days Setting)
Multiple Weekday Groups:
Apart from individual week days, pressing the "Day" button also selects
multiple day combinations such as:
- Monday thru Friday
- Saturday & Sunday
- Monday thru Saturday
- Monday & Wednesday & Friday
After setting a single day or a multi-day-combination the programmed timer
settings will be carried out on each of the week-days at the same time.
Programming Countdown Operation:
1. Press the "Timer" button to scroll through the 9 events settings to get to
the ON C setting.
2. Press the "Override" button to select whether the timer will turn ON or OFF
during teh countdown period.
3. Press the "H+" and "M+" buttons to set the hours and minutes of the
countdown.
4. Press the "Clock" button to store the setting and return to the current time
display. See the diagram below for more information.
PRESSURE PLATE
TERMINAL SCREW
MAKE SURE WIRE
INSULATION CLEARS
PRESSURE PLATE
Wired as Single Throw
CN
O COM
NC2 NO2 COM2
TO 200/240/277V LINE
LOAD
Wired as Single Throw
CN O COM
NC2 NO2 COM2
TO 24V LINE
LOAD
Wired as Single Throw
O COM NC2 NO2 COM2
CN
LOAD
- Tuesday & Thursday & Saturday
- Monday thru Wednesday
- Thursday thru Saturday
- Monday thru Sunday
LCD
(Function Figures)
Clock
(Current Time Setting)
Timer
(9 Programs Setting)
Override
(Manual ON/OFF Switched)

Advertisement

loading