Basic information about the drive system
12.10 Rules for wiring with DRIVE-CLiQ
Figure 12-30 Sample servo topology
12.10.8
Sample wiring for vector U/f drives
The following diagram shows the maximum number of controllable vector U/f drives and
extra components. The sampling times of individual system components are:
● Active Line Module: p0115[0] = 250 µs
● Motor Modules: p0115[0] = 125 µs
● Terminal Module/Terminal Board p4099 = 1 ms
520
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Drive Functions