Hitachi L300P Series Instruction Manual Supplement page 13

For inverters with model suffix of –lbrm or –hbrm
Hide thumbs Also See for L300P Series:
Table of Contents

Advertisement

L300P Supplement
Function mode
Code
Function name
b034
RUN time/Power ON time level
b035
Operation direction restrict
b036
Start reduced voltage
b037
Display selection
b080
AM adjustment
b081
FM adjustment
b082
Start frequency adjustment
b083
Carrier frequency setting
b084
Initialize mode
b085
Country code for initialization
Frequency scalar conversion
b086
factor
b087
STOP key enable
Resume on FRS cancellation
b088
mode
b090
BRD usage ratio
b091
Stop mode selection
b092
Cooling fan control
b095
BRD selection
b096
BRD ON level
b098
Thermistor selection
b099
Thermistor error level
C091
Debug mode selection
C101
UP/DWN selection
C102
Reset selection
Reset f frequency matching
C103
selection
C121
O zero adjustment
C122
OI zero adjustment
C123
O2 zero adjustment
st
H003
1
motor capacity selection
nd
H203
2
motor capacity selection
st
H004
1
motor pole selection
nd
H204
2
motor pole selection
st
H006
1
stabilized factor
nd
H206
2
stabilized factor
Option1 operation selection
P001
on error
Option2 operation selection
P002
on error
Input mode selection for
P031
Digital input option
Frequency during the
P050
loss of O,O2,OI input
U001
User1 selection
U002
User2 selection
U003
User3 selection
U004
User4 selection
U005
User5 selection
U006
User6 selection
U007
User7 selection
U008
User8 selection
U009
User9 selection
U010
User10 selection
U011
User11 selection
U012
User12 selection
NOTE (4) : See Page 2 (When O, OI, or O2 frequency reference input signal is lost)
Setting range
0.-9999./1000-6553(10000-65530)hr
00(Reverse is valid)/01(Only forward)/02(Only reverse)
00(Start reduced voltage time small)-06(Start reduced voltage time
large)
00(all display)/01(each function display)/02(User setting,main
setting)
0. - 255.
0. - 255.
0.10-9.99(Hz)
0.5-12.0(kHz) Derating enable,
00(Trip history clear)/01(Data initialization)/
02(Trip history clear + data initialization)
00(Interior)/01(EC)/02(USA)
0.1-99.9
00(valid)/01(invalid)
00(0Hz start)/01(Start f-equaling)
0.0-100.0(%)
00(deceleration
stop)/01(Free-run stop)
00(Always ON)/01(ON during run
〈After power ON, then for 5 minutes on stop is implied.〉)
00(invalid)/01(valid 〈 invalid during stop〉 )/02(valid 〈 valid during stop〉 )
330-380/660-760(V)
00(invalid)/01(Positive temperature coefficient enable)/
02 (NTC enable)
0. – 9999. (ohm)
00(No display)/01(Display)
00(No frequency data)/01(Keep frequency data)
00(Trip cancel during ON)/01(Trip cancel during OFF)/
02(Valid only during trip〈Cancel during ON〉)
00(0Hz start)/01(Start f-equaling)
0.-9999./1000-6553(10000-65530)
0.-9999./1000-6553(10000-65530)
0.-9999./1000-6553(10000-65530)
0.20-75.0(kW)
0.20-75.0(kW)
2/4/6/8(pole)
2/4/6/8(pole)
0. - 255.
0. - 255.
00(TRP)/01(RUN)
00(TRP)/01(RUN)
00(Mode 0)/01(Mode 1)/02(Mode 2)
00(invalid)/01(0Hz)/02(maximum Frequency )/03(multi speed 0)
NOTE (1)
no/d001-P050
no/d001-P050
no/d001-P050
no/d001-P050
no/d001-P050
no/d001-P050
no/d001-P050
no/d001-P050
no/d001-P050
no/d001-P050
no/d001-P050
no/d001-P050
11
Explanation of functions
LBRM/HFBM
LFU/HFU
Initial Data
Initial data
0.
00
06
00
180
60
0.50
3.0
00
02
1.0
00
00
0.0
01
00
00
360/720
00
3000.
00
00
00
01
Set on
forwarding
forwarding
Set on
forwarding
forwarding
Set on
forwarding
forwarding
Set on
forwarding
forwarding
Set on
forwarding
forwarding
4
4
100.
100.
00
00
00
00
no
no
no
no
no
no
no
no
no
no
no
no
0.
00
06
00
180
60
0.50
3.0
00
02
1.0
00
00
0.0
00
00
00
360/720
00
3000.
00
00
00
00
Set on
Set on
Set on
Set on
Set on
4
4
100.
100.
00
00
00
00
no
no
no
no
no
no
no
no
no
no
no
no