Hitachi Vector Control with the SJ300 Inverter Application Note page 13

Vector control with the sj300 inverter

Advertisement

1) Ref A:
2 A 200 ms
2) Ref A:
2 A 200 ms
3) Ref A:
2 A 200 ms
Data08. Io [H023] = 1.26 à
f (ave) =
2.98 Hz
I
=
0.40 Arms
M
T
T
T
1) Ref A:
2 A 200 ms
2) Ref A:
2 A 200 ms
Data10. Kp [H050] = 100 à
Shock at start and then OC trip
Note that these plots were made under steady state conditions, i.e. not transient data.
Ø
Transient response cannot be determined from these plots.
There is no set procedure or specific order for these tuning steps, because optimal tuning depends on
Ø
the conditions and situation of the system. Refer to Table 2 in previous section for suggestions for tuning.
© 2002 Hitachi America, Ltd.