53-1002265-01 18 March 2011 Dell PowerConnect B- Series TI24X Hardware Installation Guide...
Page 2
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell, the DELL logo,, Dell OpenManage and PowerConnect are trademarks of Dell Inc.; Microsoft, Windows, Windows Server, MS-DOS and Windows Vista are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries.
The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards. NOTE A note provides a tip, guidance or advice, emphasizes important information, or provides a reference to related information. viii Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Dell product catalog. Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues:...
Page 10
2. Click your country or region at the bottom of the page. For a full listing of countries and regions, click All. 3. In the Support menu, click All Support. 4. Choose the method of contacting Dell that is convenient for you. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
PowerConnect B-Series TI24X Configuration Guide. Hardware features This section describes the physical characteristics of the PowerConnect B-Series TI24X models. For details about physical dimensions, power supply specifications, and pin-outs, refer to Appendix A, “Hardware Specifications”. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
PC, straight-through EIA or TIA DB-9 serial cable (M/F) is included. The console port is located in the upper right of the front panel. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Vendor: Brocade Version: 1 Part# : PLRXPLSCS4371 Serial#: C847UQ04H Port 8: Type : EMPTY Port 9: Type : EMPTY Port 10: Type : EMPTY Port 11: Type : EMPTY Port 12: Type : EMPTY Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Page 14
The ports 25~28 are 10/100/1000 copper ports that use auto-sensing and auto-negotiating to determine the speed (10 Mbps, 100 Mbps, or 1000 Mbps) and mode (full-duplex or half-duplex) of the port at the other end of the link, and adjust port speed accordingly. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
This is the right LED on RJ45 On or Blinking Traffic is being transmitted or received on the copper port. No traffic is being transmitted or received on the copper port. System Power and Power Supply LEDs Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
You can remove one of the supplies without interrupting operation because the remaining power supply provides enough power for all of the ports. For power supply hardware specifications, refer to “Power supply specifications” on page 55. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Page 17
Failure to do this can result in damage to the power supply or the device, or both (the device can be running while a power supply is being installed or removed, but the power supply itself should not be connected to a power source). Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Chapter 3, “Connecting Network Devices and Checking Connectivity”. Dell PowerConnect systems ship with all of the items listed below. Please review the list and verify the contents. If any items are missing, please contact the place of purchase. Package contents Verify the package contents listed below: •...
Ensure that the physical environment where the device will be “Preparing the installation site” installed has the proper cabling and ventilation. on page 15 Install the Dell PowerConnect device on a desktop or in an “Installing the device” equipment rack. Devices may also be wall-mounted. page 15 When the device is installed, plug the PDU power cords (C13-C14) “Powering on the system”...
Installation precautions Installation precautions Follow these precautions when installing a Dell PowerConnect device. General precautions CAUTION Do not install the device in an environment where the operating ambient temperature might exceed 40°C (104°F). CAUTION Make sure that air flow around the front, sides, and back of the device is not restricted.
DANGER Do not use the handles on the power supply units to lift or carry a Dell PowerConnect device. DANGER Mount the devices you install in a rack or cabinet as low as possible. Place the heaviest device at the bottom and progressively place lighter devices above.
Page 23
The PowerConnect B-Series TI24X power supply is designed exclusively for use with PowerConnect B-Series TI24X devices. Installing the power supply in a device other than the PowerConnect B-Series TI24X will cause extensive damage to your equipment. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Page 24
DANGER Power supplies are hot swappable. However, Dell recommends that you disconnect the power supply from AC power before installing or removing the supply. The device can be running while a power supply is being installed or removed, but the power supply itself should not be connected to a power source.
“Powering on the system” on page 18. Rack mount installation For rack mount installation,the Dell PowerConnect B-Series TI24X supports the use of a two post Telco equipment rack and four post equipment rack. NOTE For additional support under the stack of switches. Use Dell 1U shelf, Dell p/n:G118R.
Page 26
Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Page 27
PowerConnect B-Series TI24X and would invalidate your warranty. Figure 5 shows how to attach the short mounting brackets. FIGURE 5 Attaching the short mounting brackets Mount the device in the rack as illustrated in Figure Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Attach the AC PDU power cords (C13-C14) to the AC connector on the rear panel as shown in Figure NOTE Align the locating notch on the underside of the AC PDU power cords (C13-C14) before inserting. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
If the links on these cables are good and the connected device is powered on, the link LEDs will light. Table 4 provides more details on specific LED conditions after system start-up. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
You need to run a terminal emulation program on the PC. 2. Open the terminal emulation program and set the session parameters as follows: • Baud: 9600 bps • Data bits: 8 • Parity: None • Stop bits: 1 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Page 31
Most PC serial ports also require a cable with a female DB-9 connector. Terminal connections will vary, requiring either a DB-9 or DB-25 connector, male or female. Serial cable options between a Dell switch or router and a PC or terminal are shown in Figure...
Page 32
As indicated in Figure 8 Figure 9, some of the wires should not be connected. If you do connect the wires that are labeled "Reserved", you might get unexpected results with some terminals. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
The procedures in this manual are intended for qualified service personnel. This chapter provides the details for connecting network devices and checking network connectivity. By default, the CLI is not protected by passwords. To secure CLI access, Dell strongly recommends assigning passwords. NOTE You can assign passwords using Brocade Network Advisor if an enable password for a Super User has been configured on the device.
4. Enter no password at the prompt. (You cannot abbreviate this command.) 5. Enter boot system flash primary at the prompt. This command causes the device to bypass the system password check. 6. After the console prompt reappears, assign a new password. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
You must configure at least one IP address using the serial connection to the CLI before you can manage the system using the other management interfaces. In addition, Dell routers require an IP subnet address for the subnet in which you plan to place them in your network.
“10/100/1000 Gigabit port pinouts” on page 53. Connecting to Ethernet or fast Ethernet hubs For copper connections to Ethernet hubs, a 10/100Base-TX or 1000Base-T switch, or another Dell PowerConnect device, a crossover cable is required (Figure 10 Figure 11). If the hub is equipped with an uplink port, it will require a straight-through cable instead of a crossover cable.
Automatic MDI or MDIX detection All 10/100/1000 Copper ports on the Dell PowerConnect B-Series TI24X devices support automatic Media Dependent Interface (MDI) and Media Dependent Interface Crossover (MDIX) detection. This feature is enabled on all Gigabit copper ports by default. For each port, you can disable auto MDI or MDIX, designate the port as an MDI port, or designate the port as an MDIX port.
You must install a fiber optic module (SFP or SFP+ transceiver) in each Gigabit Ethernet and 10-Gigabit Ethernet fiber port you want to use. You can install a new fiber optic module in a port while the Dell PowerConnect device is powered on and running.
<num>] [size <byte>] [quiet] [numeric] [no-fragment] [verify] [data <1-to-4 byte hex>] [brief] NOTE If you address the ping to the IP broadcast address, the device lists the first four responses to the ping. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
You can use the CLI. If you have configured an IP address on the device, you also can use Brocade Network Advisor. If a problem persists after taking these actions, contact Dell technical support. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Troubleshooting network connections Tracing a route To determine the path through which a Dell PowerConnect device can reach another device, enter a command such as the following at any level of the CLI on the PowerConnect device. PowerConnect> traceroute 192.33.4.7 Syntax: traceroute <host-ip-addr>...
Power supply 1 (NA - NA - Regular) present, status ok Power supply 2 not present Fan 1 ok, speed (auto): [[1]]<->2<->3 Fan 2 ok, speed (auto): [[1]]<->2<->3 Fan 3 ok, speed (auto): [[1]]<->2<->3 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
The software reads the temperature sensor and polls other hardware sensors according to the value set for the device poll time, which is 60 seconds by default. You can change the device poll time using the CLI. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Syntax: chassis poll-time <value> NOTE The <value> can be 0 - 65535 seconds. Removing MAC address entries You can remove learned MAC address entries from the Dell system MAC address table. You can remove the following entries: • All MAC address entries •...
DANGER The procedures in this manual are for qualified service personnel. The PowerConnect B-Series TI24X switch hardware components require minimal maintenance. Dell recommends that you clean the fiber- optic connectors on fiber-optic ports and the connected fiber cable each time you disconnect the cable.
5. Grasp the latch and pull the fiber optic module out of the port. FIGURE 13 Removing a fiber optic module 6. Store the fiber optic module in a safe, static-free place or in an anti-static bag. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
1. Remove the protective covering from the fiber-optic port connectors and store the covering for future use. 2. Before cabling a fiber optic module, Dell strongly recommends that the cable connectors and the port connectors are cleaned thoroughly. 3. Gently insert the cable connector or connectors (a tab on each connector should face upward) into the port connector or connectors until the tabs lock into place.
Replacing a power supply DANGER Power supplies are hot swappable. However, Dell recommends that you disconnect the power supply from AC power before installing or removing the supply. The device can be running while a power supply is being installed or removed, but the power supply itself should not be connected to a power source.
Removing an AC power supply Follow the steps to remove an AC power supply. 1. Unplug the PDU power cords (C13-C14) from the power source. 2. Disconnect the PDU power cords (C13-C14) from the power supply. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Page 52
5. Continue to pull the power supply until it is removed from the device. FIGURE 16 Removing the power supply 6. Place the power supply in an anti-static bag for storage. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Page 53
With the other hand, support the underside of the power supply, and insert the power supply into the empty power supply slot. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Page 54
The power supply is right-side up when the power connector is on the left and the fan vent is on the right. FIGURE 19 Installing the power supply Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
But, you need to replace the fan tray quickly after removing it from the device, otherwise the device will overheat. The fan tray is located in a slot at the rear of the PowerConnect B-Series TI24X . This section provides information about the following topics: Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
1. Disconnect the PDU power cords (C13-C14) from the power supply. NOTE If the device is connected with two Power supplies, you need to disconnect both the PDU power cords (C13-C14) from the device. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Page 57
5. Connect the PDU power cords (C13-C14) to the power supply (refer to “Powering on the system” on page 18). 6. Verify that the system is working properly as instructed in “Verifying proper operation” page 19. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Page 58
Replacing the fan tray Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
• (6.01 kg) 13.22 lbs single power supply Environmental considerations For optimal performance, operate or store your Dell PowerConnect B-Series TI24X device in compliance with the following environmental conditions. Operating environment TABLE 7 Operating environmental conditions for the device Description...
Most PC serial ports also require a cable with a female DB-9 connector. Terminal connections will vary, requiring either a DB-9 or DB-25 connector, male or female. Serial cable options between the PowerConnect B-Series TI24X and a PC or terminal are shown in Figure Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Pin Number MDI-X ports Pin Number Not used Not used Not used Not used Cable specifications Table 12 lists the cable specifications for the cables used with the Gigabit, and 10-Gigabit Ethernet ports. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
All power supplies are auto-sensing and auto-switching. Key features Refer to “Power supplies” on page 6 for the key features of the PowerConnect B-Series TI24X power supplies. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Storage environment TABLE 15 Storage environmental conditions for power supplies Description Range Storage temperature -40° to 85°C (-40° to 185°F) Storage humidity 95% maximum, non-condensing Storage altitude 4545.45 meter (15,000 feet) maximum Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
C14 type: UL/cUL 15A/250V, VDE 10A/250V Orientation: Ground pin up. Figure 29 shows the power plug and connector for AC power supplies. FIGURE 29 AC PDU power cords (C13-C14) plug and input connector Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Partes adentro no reparables por el operador. Refiera reparo a personal autorizado. ATTENTION Entretien et répartions internes ne sont autorisés qu'au personnel technique qualifié. GEFAHR Zugang zur Bedienung nicht erförderlich. Wartung nur durch qualifiziertes Personal. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
The PowerConnect B-Series TI24X power supply is designed exclusively for use with PowerConnect B-Series TI24X devices. Installing the power supply in a device other than the PowerConnect B-Series TI24X will cause extensive damage to your equipment. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
EN 61000-4-4 Electrical fast transient • EN 61000-4-5 Surge • EN 61000-4-6 Conducted disturbances induced by radio-frequency fields • EN 61000-4-8 Power frequency magnetic field • EN 61000-4-11 Voltage dips and sags Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
This is Class A product based on the standard of the Voluntary Control Council For Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Class A device (Broadcasting Communication Device for Office Use): This device obtained EMC registration for office use (Class A), and may be used in places other than home. Sellers and/or users need to take note of this. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Regulatory statements China RoHS Restriction on the use of certain hazardous substances in electrical and electronic equipment. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Page 75
De no hacerse así, el suministro de corriente o el instrumento podrían resultar dañados. (El instrumento puede estar encendido mientras se instala o retira un suministro de corriente, pero el suministro de corriente en sí no deberá conectado a la corriente). Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Page 76
Compare esta suma con el límite nominal para el circuito. Las capacidades nominales de corriente máximas están generalmente impresas en los instrumentos, cerca de los conectores de corriente de entrada. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Page 77
Assurez-vous que le bloc d’alimentation est correctement inséré dans l’emplacement. N’insérez jamais le bloc d’alimentation à l’envers. PRECAUCIÓN Verifique que el suministro de energía esté bien insertado en la ranura. No inserte nunca el suministro de energía en posición invertida. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Page 78
Alle Glasfaser-Schnittstellen verwenden Laser der Klasse 1. DANGER Toutes les interfaces en fibres optiques utilisent des lasers de classe 1. PELIGRO Todas las interfaces de fibra óptica utilizan láser de clase 1. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Page 79
PELIGRO Verifique que circuitos de la fuente de corriente están conectados a tierra correctamente; luego use el cordón de potencia suministrado con el instrumento para conectarlo a la fuente de corriente. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
Page 80
DANGER Power supplies are hot swappable, which means they can be removed and replaced while the chassis is powered on and running. However, Dell recommends that you disconnect the power supply from the wall outlet before removing and replacing the supply.
Page 81
Il est possible que le ventilateur tourne encore à grande vitesse. PELIGRO Procure no insertar los dedos accidentalmente en la bandeja del ventilador cuando esté desmontando el chasis. El ventilador podría estar girando a gran velocidad. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...