8. CLEANING AND INSPECTION
8-1-2. Checking the air filter
Close
Open
8-1-3. Checking the needle
8-2. Monthly cleaning and inspection
This section describes the cleaning procedures that should be carried out periodically about once a month.
8-2-1. Cleaning the control box air inlet port
69
1. Close the air cock (1).
2. Press the button (2) to release the air and water that have
collected inside the drain.
3. Once the air and water have been released, open the air
cock (1).
0455B
Always check that the tip of the needle is not broken and also
the needle is not bent before starting sewing.
0456B
Use a vacuum cleaner to clean the filters in the air inlet ports
0457B
(2) of the control box (1).
RH-9820