Advertisement

5

Remove the Cover

If you are installing options, you must remove the cover. These tools are required for cover removal and
installation of accessories:
A flat 1/4 inch screwdriver and T15 TORX® driver
An antistatic service kit (3M® 8501/8502/8503 or equivalent). This kit includes a static-dissipating work
surface, a chassic clip lead, and a wrist strap.
WARNING Before removing the cover, always disconnect the power cord and unplug telephone
cables. Disconnect the power cord to avoid exposure to high energy levels that can
cause burns when metal objects such as tools or jewelry short-circuit component
parts. Disconnect telephone cables to avoid exposure to shock hazard from ringing
voltages.
1. Turn off the HP NetServer and disconnect the power cord.
2. Unlock the top cover using the keylock on the front control panel.
3. Loosen both top cover mounting screws on the back of the HP NetServer.
4. Slide the top cover back 0.5 inches (2 cm) and lift it straight up.
CAUTION Wear a wrist strap and use a static-dissipating work surface connected to the chassis
when handling components.
6

Install Additional Memory

SIMM Installation Rules:
use only 60 ns HP SIMMs listed on the Product Reference Label on
the side of the HP NetServer chassis
all SIMMs in a bank are identical in size
two different SIMM sizes may be combined in the configurations
shown at right below
the selected configuration must match one of the Supported
Memory Configurations shown
NOTE
If your system's product number ends in "A", go to
Information Assistant to learn how to configure
memory.
Installation Instructions
1. Remove the Processing Cooling Duct Cover.
2. Determine the size of the SIMMs currently on the memory board and
the size of the SIMMs to be added. Refer to the Supported Memory
Configurations illustrations to choose the appropriate configuration.
3. Align the notch on the SIMM with the key in the socket.
J16
J14
J12
J10
J8
J6
J4
J2
Notches
4. Insert the SIMM at a 70° angle into the socket and tilt the SIMM
to 45° until the retaining clips snap into place.
45°
5. Reinstall the board, fully seating it in the connector by closing
the retaining latches and reinstalling the Processor Cooling
Duct Cover. Verify that the board is properly aligned and
seated before tightening the Processor Cooling Duct Cover
screws.
Key in Socket
Retaining latch
J15
J13
Bank 2
J11
J9
J7
J5
Bank 1
J3
J1
70°
Front Panel Key Lock
Processor Cooling
Duct Cover
One SIMM size
4-SIMM Configuration
8-SIMM Configuration
16-SIMM Configuration
Memory Board
Two SIMM sizes
Choose two of the following SIMM
sizes: 16, 32, 64 or 128
SIMM size #1
SIMM size #2
8-SIMM Configuration
16-SIMM Configuration