System software:
Navigator version
Operating System
Service pack
SPU
Model
Clock speed
No. of CPUs
BIOS
CPU cache
RAM
No. of power supplies

Local storage

I/O slots:
LANs
LAN connection
NIC:
Model
Driver
No. of NICs
SPU I\O slot
Local Storage
Physical drive location
Disk drives
Controller
SCSI bus
G.01.00 or later
Microsoft Windows NT Server 4.0, Enterprise Edition or later
SP 3 and hotfix "clusfixi", or later
HP NetServer LXr Pro Model 1
200 MHz. or faster
2-4 (at least 2 are required for each node)
1.00.09CD0L or later
Any size
128 MB minimum. Must be HP.
3
Internal or external, using any controller. Must use HP disks. See
Storage
below.
P5 – P6 - Shared storage controller (See Shared Storage )
P1 - Intra-cluster LAN
P2 - Client LAN
All others - Any other plug-in cards.
Intra-cluster LAN
HP D5954A crossover cable or any
equivalent only
The intra-cluster LAN may only be
used for cluster node
communication via a crossover
cable. It may not be used for client
communication.
HP D5013A (10/100TX PCI)
(or HP J3171A)
2.24.00.0000 or later
1
P1
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/8).
Must be HP.
SPU embedded controller or any controller (any number, manufacturer or
driver) in any available I/O slot (see
Any HP cables that meet SCSI specifications and any SCSI bus speed
2
Client LAN
Any LAN
Any that is on both the HP Tested
Products List and the Microsoft
Hardware Compatibility List.
Any driver
If the NIC used is the same as the
Intra-cluster LAN, then the Client
LAN must use the same driver as
the Intra-cluster LAN.
1 minimum
P2
SPU I/O slots
above).
Local