PLC-XU106 Expand Serial Command Functional Specifications Overview This Functional Specification defines communication functions for PLC-XU106. Compatible to Firmware Ver. 1.x of the projector. Most commands can be used to control projector remotely from PC by RS-232C. Therefore, the commands are defined as Expand Serial Commands. Serial Interface Specification 2.1 Transfer Specification Item...
PLC-XU106 Expand Serial Command Functional Specifications Notes for communication 1. Expand Serial Command is defined as one command / one line that starts with “C” and ends with carriage return (0x0D) 2. There are two types of commands: Functional Execution Command and Status Read Command.
PLC-XU106 Expand Serial Command Functional Specifications 5. Functional Execution Command Table 5.1 Image Command Table Execute command Item CF_BRIGHT_%1[CR] Set Brightness value CF_CONT_%1[CR] Set Contrast value CF_COLOR_%1[CR] Set Color value CF_TINT_%1[CR] Set Tint value CF_SHARP_%1[CR] Set Sharpness value CF_GAMMA_%1[CR] Set Gamma value CF_WBAL-R_%1[CR] Set White Balance Red value CF_WBAL-G_%1[CR]...
PLC-XU106 Expand Serial Command Functional Specifications CF_VSCALE_%1[CR] Set value of Vertical scale CF_VPOS_%1[CR] Set value of Vertical position CF_HSCALE_%1[CR] Set value of Horizontal scale CF_HPOS_%1[CR] Set value of Horizontal position 5.5 Lamp Command Table Execute command Item CF_LAMPH_%1[CR] Reset Lamp use time CF_LAMPMODE_%1[CR] Select Lamp mode 5.6 Sound Command Table...
PLC-XU106 Expand Serial Command Functional Specifications 6. Status Read Command Table 6.1 Image Status Read Command Table Status read command Item CR_BRIGHT[CR] Get Brightness value CR_CONT[CR] Get Contrast value CR_COLOR[CR] Get Color value CR_TINT[CR] Get Tint value CR_SHARP[CR] Get Sharpness value CR_GAMMA[CR] Get Gamma value CR_WBAL-R[CR]...
PLC-XU106 Expand Serial Command Functional Specifications 6.5 Screen Status Read Command Table Status read command Item CR_SCREEN[CR] Get selected screen size CR_KYSTNMODE[CR] Get setting status of Keystone Store mode CR_CORNERTESTPAT[CR] Get setting status of Test pattern for Coner correction. CR_VSCALE[CR] Get setting status of Vertical Scale CR_VPOS[CR] Get setting status of Vertical Position...
PLC-XU106 Expand Serial Command Functional Specifications 6.9 Other Status Read Command Status read command Item CR_STATUS[CR] Get setting status of Projector behavior CR_SIGNAL[CR] Get Signal Status if there is a signal or not CR_VMUTE[CR] Get setting status of No Show CR_FREEZE[CR] Get setting status of Freeze CR_PTIMER[CR]...
PLC-XU106 Expand Serial Command Functional Specifications 7. Error Code Table Error Code Contents -When the received data cannot be decoded -Parameter determination error (digit number error, including invalid value, etc.) The function is not available in the selected Mode Selected value is out of range (Not reflected) Command mismatched to Hardware (command for Optional function which is not installed) When reached upper or lower limit of increasing or...
PLC-XU106 Expand Serial Command Functional Specifications 8. Functional Execution Command 8.1 Format PC issues commands in format as below: Pattern1 : “CF_COMMAND” [CR] Pattern2 : “CF_COMMAND_”%1 [CR] CF_ : Header COMMAND : Character line %1 : Parameter (Character line) _ : Space (To separate COMMAND and Parameter) The projector decodes the received command and when it is ready to receive the next command, it returns the response.
PLC-XU106 Expand Serial Command Functional Specifications 8.4 Image Command 8.4.1 CF_BRIGHT Command Command "CF_BRIGHT_%1”[CR] "000~063” --------------- Directly select Brightness setting value "UP” ----------------------- Current Brightness setting value + 1 "DN” ----------------------- Current Brightness setting value – 1 Set Brightness value of user control The value set by this command will not be saved to projector.
PLC-XU106 Expand Serial Command Functional Specifications Unacceptable “Error Code”[CR] 8.4.5 CF_SHARP Command Command “CF_SHARP_%1”[CR] “000~015” ---------------- Directly select Sharpness setting value “UP” ------------------------ Current Sharpness setting value + 1 “DN” ------------------------ Current Sharpness setting value - 1 Set Sharpness value of user control The value set by this command will not be saved to projector.
PLC-XU106 Expand Serial Command Functional Specifications 8.4.8 CF_COLTEMP Command Command “CF_COLTEMP_%1”[CR] “000” ------ Xlow “001” ------ Low “002” ------ Mid “003” ------ High Set Color Temperature. (Available only in the normal Power ON status) The value set by this command will not be saved to the projector. Therefore, when Details turning into Stanby-mode or ALL is OFF, the value returns to original setting.
PLC-XU106 Expand Serial Command Functional Specifications 8.4.11 CF_IMAGE Command Command “CF_IMAGE_%1”[CR] “DYNAMIC” ------ Dynamic (Fixed value to enable projection with a sharp, powerful picture tone) “STAND” ---------- Standard (Image adjust value is set to factory default) “REAL” ------------ Real (Fixed value to display graphic image with natural tone) “CINEMA”...
PLC-XU106 Expand Serial Command Functional Specifications 8.5 PC Adjust Control Command 8.5.1 CF_FSYNC Command Command “CF_FSYNC_%1”[CR] “0000~0031” --------------- Directly select Fine Sync setting value “UP” -------------------------- Current Fine Sync setting value + 1 “DN” -------------------------- Current Fine Sync setting value - 1 Set Fine Sync value of PC signal The value set by this command will not be saved to projector.
PLC-XU106 Expand Serial Command Functional Specifications 8.5.4 CF_H – POS Command Command “CF_H-POS_%1”[CR] “0000~nnnn” --- Directly select Horizontal Position setting value “nnnn” shows maximum value, it is current Total Dots value - Display Dots value “UP” -------------- Current Horizontal Position setting value + 1 “DN”...
PLC-XU106 Expand Serial Command Functional Specifications 8.5.7 CF_DLINE Command Command “CF_DLINE_%1”[CR] “0100”~”nnnn” --- Directly select Display Line setting value “nnnn” shows maximum value, it is current Total Line value – Vertical Position value “UP” -------------- Current Display Line setting value + 1 “DN”...
PLC-XU106 Expand Serial Command Functional Specifications 8.6.3 CF_INPUT1 Command Command “CF_INPUT1_%1_”[CR] “ANALOG” ----------Select Analog RGB Input “YPBPR” ------------- Select Component “SCART” ------------- Select SCART Select Computer 1 input and source specified by %1 at the same time. Details (Available in normal Power ON status only). Acceptable “000”[CR] Response...
PLC-XU106 Expand Serial Command Functional Specifications Change Keystone distortion correction Details (Available in normal Power ON status only). Acceptable “000”[CR] “Error Code”[CR] “201”[CR] ----When reaching the Keystone correction limit or Response Unacceptable reaching 1 step to correction limit and “FDN”/”FUP” is received.
PLC-XU106 Expand Serial Command Functional Specifications 8.7.7 CF_CORNER-DL Command Command “CF_CORNER-DL%1”[CR] “UP” ------------ Correct the horizontal line of image upwards “DN” ------------ Correct the horizontal line of image downwards “LEFT” --------- Correct the vertical line of image to the left “RIGHT”...
PLC-XU106 Expand Serial Command Functional Specifications 8.8 Lamp Command 8.8.1 CF_LAMPH Command Command “CF_LAMPH_%1”[CR] “RST” Details Reset Lamp use time counter. (Available in normal Power ON status only). Acceptable “000”[CR] Response Unacceptable “Error Code”[CR] 8.8.2 CF_LAMPMODE Command Command “CF_LAMPMODE_%1”[CR] “HIGH” ------------ Set lamp to High mode “NORMAL”...
PLC-XU106 Expand Serial Command Functional Specifications 8.9 Sound Command 8.9.1 CF_VOLUME Command Command “CF_VOLUME_%1”[CR] “000-063” -------------------------- Directly select Volume setting value “UP” --------------------------------- Current Volume setting value +1 “DN” --------------------------------- Current Volume setting value -1 Control Volume value. (Available in normal Power ON status only). The same operation of Volume Up/Down as projector and RC, and directly select Volume setting value.
PLC-XU106 Expand Serial Command Functional Specifications 8.10.4 CF_AUTOSETUPPCADJ Command Command “CF_AUTOSETUPPCADJ_%1”[CR] “ON” ------------------- Set Auto PC ADJ. function to ON “OFF” ------------------ Set Auto PC ADJ. function to OFF Set/Cancel Auto PC adj. function. (Available in normal Power ON status only). Details Note) It is unable to set Keystone, PC ADJ.
PLC-XU106 Expand Serial Command Functional Specifications 8.10.10 CF_CEIL Command Command “CF_CEIL_%1”[CR] “ON” ------------------------ Set Ceiling to ON “OFF” ----------------------- Set Ceiling to OFF Set/Cancel Ceiling setting. (Available in normal Power ON status only). Details The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF.
PLC-XU106 Expand Serial Command Functional Specifications 8.10.14 CF_ON-STA Command Command “CF_ONÿ STA_%1”[CR] “ON” --------------------------- Set Power On Start to ON “OFF” ------------------------- Set Power On Start to OFF “UP” --------------------------- Switch setting (On → Off → On → ÿ e ÿ e ÿ e ) “DN”...
PLC-XU106 Expand Serial Command Functional Specifications 8.10.21 CF_FANMODE Command Command “CF_FANMODE_%1”[CR] “L1” ---------------------------- Set Fan Mode to L1 “L2” ---------------------------- Set Fan Mode to L2 Switch Fan Mode. (Available in normal Power ON status only). When L1 is selected, fan noise after POWER OFF is louder. Details When L2 is selected, fan noise after POWER OFF becomes quiet, however, fan rotates longer than L1.
PLC-XU106 Expand Serial Command Functional Specifications 8.10.25 CF_FDEFAULT Command Command “CF_FDEFAULT_%1”[CR] “RST” Set the value to Factory Default Details (Available in normal Power ON status only). Acceptable “000”[CR] Response Unacceptable “Error Code”[CR] 41 / 68...
PLC-XU106 Expand Serial Command Functional Specifications 8.11 Other Command 8.11.1 CF_KEYENU Command Command “CF_KEYENU_%1”[CR] “RIGHT” ------------------------- Shift Pointer on OSD Menu to right “LEFT” --------------------------- Shift Pointer on OSD Menu to left “UP” ------------------------------ Shift Pointer on OSD Menu to right “DN”...
PLC-XU106 Expand Serial Command Functional Specifications 8.11.4 CF_FREEZE Command Command “CF_FREEZE_%1”[CR] “ON” ------------------------ Set Freeze to ON “OFF” ----------------------- Set Freeze to OFF “UP” ------------------------------ Switch setting (On → Off → On → ÿ e ÿ e ÿ e ) “DN”...
PLC-XU106 Expand Serial Command Functional Specifications 9. Status Read Command 9.1 Format PC issues commands in format as below: “CR_Command” [CR] Command : Character Line When projector receives the appropriate command, it returns a character line as the required data “000ÿ...
PLC-XU106 Expand Serial Command Functional Specifications 9.4 Image Status Read Command 9.4.1 CR_BRIGHT Command Command “CR_BRIGHT”[CR] Details Get Brightness value of user control Acceptable “000_ÿ ÿ A ”[CR] Response “000”~“063” Unacceptable “Error Code”[CR] 9.4.2 CR_CONT Command Command “CR_CONT”[CR] Details Get Contrast value of user control Acceptable “000_ÿ...
PLC-XU106 Expand Serial Command Functional Specifications 9.4.6 CR_GAMMA Command Command "CR_GAMMA”[CR] Details Get Gamma value of user control Acceptable “000_%a”[CR] Response “000”~“015” Unacceptable “Error Code”[CR] 9.4.7 CR_WBAL – R Command Command "CR_WBAL-R”[CR] Details Get White Balance Red value of user control Acceptable “000_%a”[CR] Response...
PLC-XU106 Expand Serial Command Functional Specifications 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command "CR_FSYNC”[CR] Details Get Fine Sync value Acceptable “000_%a”[CR] “0000”~“0031” Response “Error Code”[CR] ----- When the command is invalid due to Unacceptable condition such as Input source 9.5.2 CR_TDOTS Command Command...
PLC-XU106 Expand Serial Command Functional Specifications 9.5.6 CR_DDOTS Command Command “CR_DDOTS”[CR] Details Get Display Dots value Acceptable “000_%a”[CR] “0256”~“nnnn” Response (nnnn = Total Dots – Horizontal Position value) “Error Code”[CR] -------- When the command is invalid due to Unacceptable condition such as Input source 9.5.7 CR_DLINE Command Command...
PLC-XU106 Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command “CR_SERSYS”[CR] Get currently selected signal Details Returns auto-detected signal in Auto mode Only available for Video input. (N/A when Input is computer) Acceptable “000_%a”[CR] “1080I60” -------------- 1080i 60Hz “1080I50”...
PLC-XU106 Expand Serial Command Functional Specifications 9.7.8 CR_SYSLIST Command Command “CR_SYSLIST”[CR] Details Get selectable System titles Acceptable “000_%1_%2_..._%x” [CR] - When Input is PC-Analog “XGA1” ------------ XGA1is selectable “1080I ” ----------- 1080i is selectable Projector does not return Auto,Mode1-5 When there is no signal, it returns Error Code “101” -When Input is Y,Pb/Cb,Pr/Cr Returns all the System titles on Menu including Auto “AUTO”...
PLC-XU106 Expand Serial Command Functional Specifications 9.8.5 CR_VPOS Command Command “CR_VPOS”[CR] Details Get setting status of Vertical Position Store Mode Acceptable “000_%1”[CR] Response “-15” ~ “015” Unacceptable “Error Code”[CR] 9.8.6 CR_HSCALE Command Command “CR_HSCALE”[CR] Details Get setting status of Horizontal Scale Store Mode Acceptable “000_%1”[CR] Response...
PLC-XU106 Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command “CR_LAMPREPL”[CR] Details Get information of Lamp Replacement time Acceptable “000_%1”[CR] “1Y” -------------------------- Over lamp replacement time “1N” -------------------------- Within lamp replacement time “1” means the number of lamps. Response (1 lamp model→...
PLC-XU106 Expand Serial Command Functional Specifications 9.9.5 CR_LAMPMSTS Command Command “CR_LAMPSTS”[CR] Details Get Lighting status of lamp Acceptable “000_%1”[CR] “ÿ N **** ” A number of * should be among 1-4. First character shows how many lamps are incorporated in projector.
PLC-XU106 Expand Serial Command Functional Specifications 9.10 Sound Status Read Command 9.10.1 CR_VOLUME Command Command “CR_VOLUME”[CR] Details Get Volume value of user control Acceptable “000_%a”[CR] Response “000”~“063” Unacceptable “Error Code” [CR] 9.10.2 CR_MUTE Command Command “CR_MUTE”[CR] Details Get sound mute setting status Acceptable “000_%a”[CR] “ON”...
PLC-XU106 Expand Serial Command Functional Specifications 9.11 Setting Status Read Command 9.11.1 CR_LANG Command Command “CR_LANG”[CR] Details Get selected language Acceptable “000_%a”[CR] “ENG” -------------------------- English is selected “DEU” -------------------------- German is selected “FRA” -------------------------- French is selected “ITA” --------------------------- Italian is selected “ESP”...
PLC-XU106 Expand Serial Command Functional Specifications 9.11.5 CR_BACKGND Command Command “CR_BACKGND” [CR] Details Get setting status of Screen for no signal Acceptable “000_%1” [CR] “BLUE” -------------------------------- Blue Back is selected Response “USER” ------------------------------- User is selected “BLACK” ------------------------------ Black Back is selected Unacceptable “Error Code”...
PLC-XU106 Expand Serial Command Functional Specifications 9.11.10 CR_P-MANE Command Command “CR_P-MANE”[CR] Details Get Power management setting status Acceptable “000_%a”[CR] “OFF” -------------------------- Power Management is OFF Response “READY” ---------------------- Power Management is Ready “SHUTDOWN” ---- Power Management is set to Shut Down mode Unacceptable “Error Code”...
PLC-XU106 Expand Serial Command Functional Specifications 9.11.20 CR_PJLOCKMENU Command Command “CR_PJLOCKMENU” [CR] Details Get status of PJ Lock on Menu Acceptable “000_%1[CR] “ON1” ------------- PJ Lock status is On-1 Response “ON2” ------------- PJ Lock status is On-2 “OFF” ------------- PJ Lock status is OFF Unacceptable “Error Code”...
PLC-XU106 Expand Serial Command Functional Specifications 9.12 Other Status Read Command 9.12.1 CR_STATUS Command Command “CR_STATUS”(CR) Get status of Projector behavior. Details This command affects the same as ”CR0” of Basic Serial command, but this has an error code. Acceptable “000_%1”[CR] “00”= Power ON “80”= Stand by...
PLC-XU106 Expand Serial Command Functional Specifications 9.12.5 CR_PTIMER Command Command "CR_PTIMER”[CR] Details Get status of Presentation Timer Acceptable “000_%a”[CR] “ON” -------------------- Presentation timer is in operation Response “STOP” ----------------- Presentation timer is paused “OFF” ------------------- Presentation timer is not operating Unacceptable “Error Code”...
PLC-XU106 Expand Serial Command Functional Specifications 9.12.7 CR_TEMP Command Command "CR_TEMP”[CR] Get current temperature inside a projector. Details If there are several sensors installed, it is possible to get information from all the sensors at once. Acceptable “000_%1_%2_%3”[CR] %1= Sensor 1 temperature (Outside temperature) %2= Sensor 2 temperature (Inside temperature1) %3= Sensor 3 temperature (Inside temperature2) %1,%2 are consists of 6 bites fixed...
PLC-XU106 Expand Serial Command Functional Specifications 9.12.8 CR_TEMPFAIL Command Command "CR_TEMPFAIL”[CR] Get the temperature inside a projector when abnormal temperature occurs. Details If there are several sensors installed, it is possible to get information from all the sensors at once. Acceptable “000_%a_%b_%c”[CR] %a ------------------ Sensor 1 temp.