HP D5970A - NetServer - LCII Configuration Manual page 6

Microsoft cluster with hp rack storage/12fc and hp rack storage/12
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

SPU
Model
Clock speed
No. of CPUs
BIOS version
CPU cache
RAM
Local storage
I/O slots:
Storage
Local
Controller
Cabinets (Physical drive
location)
Disk drives (hot swap or
fixed)
SCSI bus
SCSI Ids
Shared
HP Rack Storage/12FC
Host Bus Adapter
Model
No. of HBAs
Driver
SPU I/O slot
RAID level
Cabinet
RAID arrays
No. of cabinets
FC Array Cards
Model
No. of cards/cabinet
Firmware
Status SCSI ID
Disk SCSI IDs
HP NetServer LPr
400, 450, 500, 550, 600, 650, 700 MHz. or higher
2
4.06.09 PR or later (400, 450 MHz with Rack Storage/12 D5989A)
4.06.14.PR or later (400, 450 MHz with Rack Storage/12 D5989B)
4.06.14.PR or later (500, 550 MHz with Rack Storage/12 D5989B)
4.06.29.PR or later (600, 650, 700 MHz with Rack Storage/12 D5989B)
Any size
64 MB minimum. Must be HP.
See Local Storage below.
P1 – Free or NetRAID Local StorageBus Adapter
P2 – Client LAN
P3 – Host Bus Adapter (Shared Storage)
P4 – Intra-cluster (Heartbeat) LANs
May use embedded SCSI controller, NetRAID-1, NetRAID-3, NetRAID-
3Si in PCI slot P1.
May not use NetRAID-1Si.
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Must be HP.
Any HP cables that meet SCSI specifications and any SCSI bus speed.
Any
(Required)
HP D8602A
1
1.12 or later
P3
0, 1, 3, 5, or 0 & 1
Not more than 8 physical drives per logical array and not more than 8
LUNs are permitted per Rack Storage/12FC and Rack Storage/12
combination in a cluster.
1
D5990A
1 - Simplex (Supplied with Rack Storage/12FC.)
2 - Duplex (Additional card required in the Rack Storage/12FC.)
4.64-00 or later
5 (fixed)
0 – 3, 8 – 15 (fixed)
2

Advertisement

Table of Contents
loading