AN1600 F1 Network Storage System Quick Specification
System Cooling
Thermal Feature
Compliance
System inlet
temperature
Relative
humidity
(non-condensing)
Acoustic noise
EMI Considerations
Emissions
Support 10° to 35° C (50° to 95° F) environment
Two CPU heat-sink (2U height) supporting Intel Xeon processors up
to TDP 95W
Support memory full-populated configuration
Support up to 12*SAS/SATA HDDs
3+1 hot plug, redundant system fans with PWM controlled MB
System fans support PWM fan speed control with SMART FAN
feature
Common used for Acer 2U server platforms
Windows Hardware Logo Program Requirements
ACPI 3.0b
PCI-E 2.0 for Gen2
PXE 2.1
WOL
SMBIOS 2.6.1
IPMI 2.0
Operating
Non-operating
Operating
Non-operating
Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23° C ambient environment.
Noise emissions were measured in accordance with ISO 7779
Idle
LWAd
LpAm
Operating
LWAd
LpAm
Adequate EMC shielding to meet Class A of EMC requirements (FCC,
CE, BSMI)
Chassis seams have features to enhance grounding
Motherboard mounting features provides grounding
Normative standards : CISPR 22; EN55022; EN55024; FCC CFR 47,
Pt 15; ICES-003; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC
60950-1
FCC rating
10° to 35° C (50° to 95° F) at sea level with an
altitude derating of 1.0° C per every 305 m
(1.8° F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft)
-40° to 70° C (-40° to 158° F).
8 to 90% relative humidity (Rh), 28° C
(82.4° F) maximum wet bulb temperature,
non-condensing
5 to 95% relative humidity (Rh), 38.7° C
(101.7° F) maximum wet bulb temperature,
non-condensing
5.1BA
40dBA
5.7BA
44dBA
Class A
12