AN1600 F1 Network Storage System Quick Specification
System Cooling
Thermal Feature
Compliance
System inlet
temperature
Relative
humidity
(non-condensing)
Acoustic noise
EMI Considerations
Emissions
Support 10° to 35° C (50° to 95° F) environment
•
Two CPU heat-sink (2U height) supporting Intel Xeon processors up
•
to TDP 95W
Support memory full-populated configuration
•
Support up to 12*SAS/SATA HDDs
•
3+1 hot plug, redundant system fans with PWM controlled MB
•
System fans support PWM fan speed control with SMART FAN
•
feature
Common used for Acer 2U server platforms
•
Windows Hardware Logo Program Requirements
•
ACPI 3.0b
•
PCI-E 2.0 for Gen2
•
PXE 2.1
•
WOL
•
SMBIOS 2.6.1
•
IPMI 2.0
•
Operating
Non-operating
Operating
Non-operating
Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23° C ambient environment.
Noise emissions were measured in accordance with ISO 7779
Idle
LWAd
LpAm
Operating
LWAd
LpAm
Adequate EMC shielding to meet Class A of EMC requirements (FCC,
CE, BSMI)
Chassis seams have features to enhance grounding
Motherboard mounting features provides grounding
Normative standards : CISPR 22; EN55022; EN55024; FCC CFR 47,
Pt 15; ICES-003; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC
60950-1
FCC rating
10° to 35° C (50° to 95° F) at sea level with an
altitude derating of 1.0° C per every 305 m
(1.8° F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft)
-40° to 70° C (-40° to 158° F).
8 to 90% relative humidity (Rh), 28° C
(82.4° F) maximum wet bulb temperature,
non-condensing
5 to 95% relative humidity (Rh), 38.7° C
(101.7° F) maximum wet bulb temperature,
non-condensing
5.1BA
40dBA
5.7BA
44dBA
Class A
12