Download Print this page

Samsung P63F - 63" Plasma Panel Control Protocol page 67

Multiple display control protocol
Hide thumbs Also See for P63F - 63" Plasma Panel:

Advertisement

SEC-VD-DSW External Control
* Safety Screen Run Control
Function
Personal Computer will make Safety Screen function to operate immediately, not by
Timer operation.
Safety Screen Run
Get
Header
0xAA
Safety Screen Run
Set
Header
0xAA
Safety Screen Type
0
1
2
3
4
6
Ack
Header
0xAA
Safety Screen Type
Nak
Header
0xAA
ERR
: Error code that shows what occurred error is
Status
Command
ID
0x59
Command
ID
0x59
: Safety Screen Type to be set on TV/Monitor (1~6)
Off
Signal Pattern
All White
Scroll
Bar
Eraser
Command
ID
0xFF
: Same as above
Command
ID
0xFF
Data Length
Check
Sum
0
Data 1
Data Length
Safety
1
Screen
Type
Ack/Nak
Data Length
3
'A'
Ack/Nak
Data Length
3
'N'
Check
Sum
r-CMD
Val 1
Safety
0x59
Screen
Type
r-CMD
Val 1
0x59
ERR
Check
Sum
Check
Sum
66

Advertisement