HP A3550A - High Availability Disk Arrays Model 20 Storage Enclosure User Manual page 133

High availability scsi disk array
Hide thumbs Also See for A3550A - High Availability Disk Arrays Model 20 Storage Enclosure:
Table of Contents

Advertisement

ÃÃ
Failing
Continue after
component
failure?
Disk module
Yes
SP
No
Fan pack
Yes
Power supply
Yes
SCSI-2 adapter/
No*
cable
5-10
What happens and how to recover
With RAID of any level supported by MPE/iX, applications
continue running. System Administrator or service provider
replaces module.
Provides the same features as the basic configuration, but
with better performance and higher availability. With RAID of
any supported level, applications can continue to run after the
failure of a single disk module.
If an SP fails, the System Administrator must reassign
ownership of the failed SP's LUNs to the operational SP by
using Grid Manager. Also, the path to the operational SP must
be used and can be changed using SYSGEN or ioconfig.
Once these changes have been made, access to all LUNs on
the array within the SCSI LUN limits is possible. LUN
ownership need to be reassigned by using Grid Manager.
Applications continue running. System Administrator or
service provider replaces module.
If a redundant power supply module is present, applications
continue running; otherwise, disk array fails. Service provider
replaces power supply. The System Administrator restarts the
operating system if necessary.
If the adapter/cable fails, LUN ownership and path changes
may be made using Grid Manager and
SYSGEN/ioconfig, respectively.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Net pc 20