Installing the riser board

To install the riser board, reverse the removal procedure:
Attach the board to the chassis, securing it with the thumbscrew.
1.
Install the access panel.
2.
Insert the enclosure into the rack and power up the enclosure.
3.

Verifying component replacement

After replacing the riser board, be sure there is power to the 7-segment display board.

Midplane

Before you begin

CAUTION:
Before removing the failed component, make sure that you have the replacement part available.
Removing a component impacts the airflow and cooling ability of the device.
Do not remove more than one component or blank from the enclosure at a time. Doing so impacts
the airflow and cooling ability of the device. To avoid possible overheating, insert the new or
replacement component as quickly as possible. If the internal temperature exceeds acceptable limits,
the MSA70 may overheat and automatically shut down or restart.
Parts can be damaged by electrostatic discharge. Use proper anti-static protection.

Verifying component failure

Use the following methods to verify component failure:
Check the host log for errors.
Check the following component status LEDs as identified in the following tables:
Hard drives—test with known good hard drives.
I/O module—test with known good I/O module.
Fan module—test with known good fan module.
Hard drive LED combinations
Online/activity LED
(green)
On, off, or flashing Alternating amber
On, off, or flashing Steadily blue
On
On
Fault/UID LED
Interpretation
(amber/blue)
The drive has failed, or a predictive failure alert has been
and blue
received for this drive; it also has been selected by a
management application.
The drive is operating normally, and it has been selected by a
management application.
Amber, flashing
A predictive failure alert has been received for this drive.
regularly (1 Hz)
Replace the drive as soon as possible.
Off
The drive is online, but it is not currently active.
Removal and replacement procedures 45