Hour Meter; Power Meter; Ac Pilot Light (Green) - Yamaha EF6300iSDE - 5500 Watt Inverter Generator Owner's Manual

Owners manual
Table of Contents

Advertisement

1
2
1
NOTE:
If you operate the generator with the voltage select
switch in the 120/240V-position, the electric current
will be limited for the 120V-receptacles.
When you use either receptacle 1 or 2 AND recepta-
cle 3 at the same time, the total electric current pro-
3
793-7CKf
vided will be equal to or even less than 22.9A.
For example:
If the 240V-receptacle provides 10A, the 120V-recep-
tacles 1 and 2 can be used up to 12.9A each.
In case the load exceeds 22.9A, the overload indicator
light will turn on and the generator will stop. (At this
moment the segments of the powermeter may not
reach 10)
If you operate the generator with the voltage select
switch in the 120V-position, the receptacles 1 and 2
can supply rated current (45.8A).

Hour meter

1
The hour meter 1 shows the total number of hours
the generator has been run.
763-7CKf

Power meter

The power meter 1 shows the amount of electric cur-
1
rent used by a barmeter.
The generator output is normal when the segments of
the barmeter appear.
NOTE:
763-7CKg
When 10 segments appear, the generator has almost
reached its rated output.

AC pilot light (green)

The AC pilot light 1 comes on when the engine starts
and produces power.
763-7CKc
– 10 –