Download Print this page

HP 124708-001 - ProLiant Cluster - 1850 Troubleshooting Manual page 15

System memory troubleshooting best practices for hp proliant servers
Hide thumbs Also See for 124708-001 - ProLiant Cluster - 1850:

Advertisement

For more information on how to deploy firmware updates remotely, refer to the following URL:
http://h18004.www1.hp.com/products/servers/management/im/index.html
Customer Advisory
c00683436, Online ROM Flash Tool Available For Updating Firmware On ProLiant
Servers And Options, is available at:
http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c00683436
Updating Firmware Using the OFFLINE ROM Flash Method
The Offline ROM Flash, as its name implies, is performed when the server is taken down for regular
maintenance. Although the results will be the same, the Offline ROM Flash does not provide the same benefits
of the new Online ROM Flash method. In addition, when upgrading remotely, the server administrator can
only update one server at a time.
There are two methods of performing an Offline ROM Flash. The firmware can be updated using a ROMPaq
Diskette or using the ROM Update Utility.
A ROMPaq is a floppy-disk based method of upgrade. The firmware is downloaded onto a floppy diskette
and then the system is booted to the floppy drive.
The ROM Update Utility is located on the Firmware Maintenance CD, or can be downloaded to a USB Drive
Key using the HP Drive Key Boot Utility.
Note: Hard Drive components can only be updated using the Offline method.
The HP Drive Key Boot Utility
The HP Drive Key Boot Utility can format an HP Drive Key so that it can be used as a bootable device. The
utility also provides the ability to load the ROM Update Utility on an HP Drive Key. After the ROM Update
Utility has been installed, the Offline ROM Flash Smart Components can be downloaded to the drive key from
the following URL and deployed using the ROM Update Utility:
http://h18023.www1.hp.com/support/files/server/us/smartstartGP.html
System ROM support is required for the HP Drive Key Utility. To determine server support, refer to the
following URL:
http://h18004.www1.hp.com/products/servers/platforms/usb-support.html
For additional information on the HP Drive Key Boot Utility, refer to the following URL:
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00218060/c00218060.pdf
15

Advertisement

loading

This manual is also suitable for:

Bl10e - hp proliant - 512 mb ramCl380 - proliant - 256 mb ramDl380 - proliant - g2Proliant cl1850226824-001 - proliant - ml750234664-002 - proliant - ml330t02 ... Show all