Download Print this page

GE Arctica G LINE PHG25PGT Series Technician Manual page 24

Side-by-side dual evaporator refrigerators with electronic touch controls

Advertisement

Inverter
• The inverter is accessed from the back of the
refrigerator.
• It is mounted directly on the left side of the
compressor.
• The water valve must be removed to access
the inverter.
To remove the Inverter
1.
To remove the inverter, remove the single
Phillips screw on the lower right side. Lift the
inverter up and off the compressor bracket.
Caution: It may be necessary to bend the
process tube in order to remove the inverter. If
iit is necessary to bend the process tube, use
extreme caution.
WARNING: When the refrigerator is plugged in,
240 VAC is always present at the inverter.
Note: Certain voltmeters will not be able to read
voltage output from the inverter. If no voltage or
erratic voltage is measured, it does not neces-
sarily indicate a faulty inverter.
The inverter receives 240 VAC line-in from the
power supply. The inverter converts this single
phase, 50 Hz, 240 VAC into 3-phase, 230 VAC,
with frequency variations between 57 Hz and
104 Hz. This voltage is delivered to the com-
pressor through 3 lead wires. Each wire will
carry identical voltage and frequency.
Note: The compressor leads must be connected
to measure voltage output. If the compressor
wires are not connected, or if an open occurs in
one of the 3 lead wires or in the compressor, the
inverter will stop voltage output.