Troubleshooting - Husqvarna Aspire P5-P4A Operator's Manual

Hide thumbs Also See for Aspire P5-P4A:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
3. Make sure that the terminals on the battery and the
battery charger are clean before use.
4. Clean the inner surface of the protective cover with a
brush.
To examine the battery and the battery
charger
1. Examine the battery for damages, for example
cracks.
User interface Aspire P5-P4A
Problem
Possible faults
Green start LED
Low battery voltage.
flashes.
Red error LED flash-
Overload.
es.
Temperature deviation.
The power trigger and the start button are
pushed at the same time.
Green LED and red
The battery is empty.
LED flash alternately.
The battery is damaged.
Troubleshooting of the battery charger
LED on the battery
Cause
charger
The green LED is
The battery is not correctly instal-
on and the red LED
led in the battery charger.
flashes.
The battery connectors are dirty.
The ambient temperature is too
high or too low.
The battery is damaged.
1867 - 007 - 10.01.2024
2. Examine the battery charger for damages, for
example cracks.
3. Make sure that the connection cord of the battery
charger is not damaged and that there are no cracks
in it.

Troubleshooting

Possible solution
Charge the battery.
The cutting attachment is blocked. stop the
product. Remove the battery. Clean the cut-
ting attachment from unwanted materials.
Loosen the chain.
Let the product become cool.
Release the power trigger and push the start
button.
Charge the battery.
Speak to your servicing agent.
Solution
Remove the battery from the charger and install the bat-
tery in the battery charger again.
Clean the battery connectors.
Use the battery charger in temperatures between 0 °C –
+35 °C.
Replace the battery.
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aspire pe5-p4a

Table of Contents