EDIT - COMMAND Key - SETINIT [Register Initial Parameter Values]
Version 2 lets you select the initialization type: either current or factory.
When you turn the knob to select current, the screen displays the name of the currently
selected sample.
EDIT - COMMAND Key - FREZ_SB
This is a new command. The command can be accessed from any EDIT-mode function.
The command "freezes" the sample bank's sound by copying the bank's parameter set-
tings directly into the samples within the bank. After completing the copy, the com-
mand reinitializes the sample bank's settings.
• Push Knob 1 to execute the command.
• Turn Knob 2 or Knob 3 to select the operation type. You can select from three types,
EDIT - COMMAND Key - COPY_PRM
This is a new command. The command can be accessed from any EDIT-mode function.
This command copies parameter settings from a selected sample or bank into the cur-
rently selected sample or bank.
All settings are copied, with the exception of the following:
Use Knob 2 or Knob 3 to select the sample or bank from which settings are copied.
current
Register the selected sample's current values as the defaults.
factory
Use the A3000 factory defaults.
as follows.
param
Copy settings as described above.
LpMode
Change loop mode for all samples to the mode selected by Knob 4.
(But do not copy setting.)
param&LpMode After copying settings into samples, change loop mode for all sam-
ples to the mode selected by Knob 4.
Original Key, Fine Tune, Key Range Low, Key Range High, Loop Mode, Wave Ad-
dresses, Loop Addresses
Changes in EDIT MODE
[Freeze Sample Bank]
[Copy Parameters]