HP 3325B Operating Manual page 114

Synthesizer/function generator
Hide thumbs Also See for 3325B:
Table of Contents

Advertisement

Specifications
Table 3-1. Specifications, Continued
Phase Modulation
Sine Function Range:
±850°, ±5V input
Sine Function-Linearity:
± 0.5%, best fit straight line
Squarewave Range: ±425°
Triangle Range: ±42.5°
Positive and Negative Ramps: ± 85°
Modulation Frequency Range: DC - 5 kHz
input Impedance: >40kQ
Connector: Rear panel BNC
Frequency Sweep
Modulation Source:
Frequency Range: Sine 0.1 Hz-10 kHz, Square 0.1
Hz-2 kHz
Frequency Resolution: 2 digits
Frequency Accuracy: Typically
0
.
1
% (Srnewave)
Amplitude Range: 0,1 Vppto12Vpp
Amplitude Resolution; 0.1V
Amplitude Accuracy: Typically ± 200 mV
Impedance: Designed to drive & 10 kQ loads
Sinewave Purity: Typically better than - 34 dBc
Standard Waveforms: Sine, Square
Arbitrary Waveforms: Vertical resolution 256
points, horizontal resolution 4096 points, 300,000
samples/sec, 10 kHz maximum.
Output Location: Rear Panel BNC
Sweep Time:
Linear; 0.01s to 1000s
Logarithmic: 1s to 1000s single, 0.1s to lOQOs
continuous
Maximum Sweep Width:
Full frequency range of the main signat output for
the wave form in use except minimum log start
frequency is 1 Hz.
Minimum Sweep Width:
Function
Minimum sweep width
Sweep time
.01 sec.
Sweep time
99,9 sec.
Sine
.1 mHz
999.9 mHz
Square
.05 mHz
499.5 mHz
Triangle
.005 mHz
49.95 mHz
Ramps
.01 mHz
99.99 mHz
Minimum log sweep width is 1 decade.
Phase Continuity:
Sweep is phase continuous over the full frequency
range of the main output.
Discrete Sweep:
Number of segments; 100 maximum (Start and
stop frequencies settalbe for each segment)
Time/segment: O.OIsto 1000s, O.OIs resolution.
3-8