3 I N S TA L L AT I O N
L i n e C o r d W i r e C o l o r
Des cri pti on
Typical Connection for
-48 V dc System
Connect to negative terminal of
4 8 V d c s o u r c e .
Return (+)
Connect to positive terminal of
48 V dc source. Positive
terminal of 48 V dc source may
be connected to chassis ground.
Green with yellow stripe
C h a s s i s G r o u n d
Connect to chassis ground.
Confirming Correct Installation
After applying power to the OM 2000, there Is short initialization period. If the
i n s t a l l a t i o n i s c o r r e c t ;
• The green power indicator is on.
• The RF, IF, and FAULT SUMM LEDs may illuminate red to indicate a configuration
When the above sequence is observed, the unit can be configured. Refer to
Section 4, "Setup and Operation" for information on preparing the unit for operation,
if the above conditions do not occur, refer to Section 5, "Troubleshooting."