PAC2000S12-B1 PSU
Table 9-15 IP PRESENT# signal characteristics
Signal Characteristics
IP PRESENT# = High
IP PRESENT# = Low
Table 9-16 IP PRESENT# output
IP PRESENT# Output
Low level voltage
High level voltage
Source current, IP PRESENT# = Low
Source current, IP PRESENT# = High
Signal rise and fall time

9.12 PS_INTERRUPT#

The PS_INTERRUPT# signal indicates PSU I2C alarm interruption.
Table 9-17 PS_INTERRUPT# signal characteristics
Signal Characteristics
Signal type: I2C alarm interruption
signal
PS_INTERRUPT# = High
PS_INTERRUPT# = Low

9.13 EFUSEV

The system samples the input current of the main service load branch (12 V), converts the current
to a linear voltage analog signal, and sends the signal to the EFUSEV pin of the PSU.
Technical Manual
Min.
0 V
2.000 V
PSU side: OD gate output. There is no pull-up on the PSU
side, or the DSP directly outputs the signal through a
series resistor.
System side: After the signal is pulled up to 3.3 V, it is
sent to the system reversely through the MOSFET.
PSU normal
PSU alarm
MV12 output mode
SV12 output mode
Max.
0.6 V
3.465 V
4 mA
4 mA
200 μs
41