Recording Level Adjustment
Mode
input signal & test tape
Adjustment location
Measuring location
Adjustment value
Remarks
STOP
Set the TAPE
SELECTOR switch to the NORM position.
PAUSE | (316mV) signal to the LINE
TP2 (R ch)
2)
REC.
Apply a 315Hz/-10dBv
REC
LEVEL control
TP1 {L ch)
-7.7dBv (412.1mV)
INPUT terminals.
7.
1
3
Set the DOLBY
NR switch to the ON position.
4
REC/
Record the above signal level
V103 (Left channe!)
TP1 (L ch)
-7.7dBv (412.1mV)
PLAY
onto the STD-608A test tape,
V203 (Right channel)
TP2 (R ch)
and playback.
Record the above signal onto
Confirm
TP1 (L ch)
-7.7dBv+1.5dB
the STD-603 test tape, and
TP2 (R ch)
playback.
5 |
Set the TAPE
SELECTOR
switch to the CrO2 position.
7
Set the TAPE
SELECTOR
switch to the METAL
position.
Record the above signal onto
Confirm
TP1 (L ch)
-7.7dBv+1.5dB
the STD-610 test tape, and
TP2 (R ch)
playback.
8.
Copy Mode Frequency Response Check
@ To be executed after all other adjustments have been completed.
Input signal & test tape
Adjustment location
Measuring location
Adjustment value
Remarks
STOP
Set the TAPE
SELECTOR
switch to the NORM
position.
COPY &|
Load the STD-331B
test tape
Copy recorded signal from STD-33 1B
(at
ii
into deck |, and the STD-
both normal and double speeds)
PLAY
(Deck
I)
The allowable zone
shown in Fig.10-9 is to
be satisfied.
Play the signal recorded on
Left and right
the STD-608A test tape
in the previous adjustment
procedure.
Set the TAPE
SELECTOR
switch to the CrO2 position.
608A test tape into deck II.
Load the STD-603 test tape into deck II, and repeat steps 1 and 2 to check that the allowable zone shown in Fig. 10-9 is satisfied.
STOP
Load the STD-610 test tape into deck II, and repeat steps 1 and 2 to check that the allowable zone shown in Fig. 10-9 is satisfied.
Set the TAPE
SELECTOR
switch to the METAL position.
38

Advertisement

loading

This manual is also suitable for:

Ct-1060w(bk)Ct-s77wCt-s77w(bk)