Performance Tests; Dc Ammeter Accuracy Test; Ohms Accuracy Test; Ac Voltage Accuracy Test - HP 3465B Operating And Service Manual

Table of Contents

Advertisement

Section V
PERFORMANCE TESTS
Model 3465B
Table 5-3. DC Ammeter Accuracy Test.
Multimeter
Range
Current
Level
Ra
Differential
VM Reading
Multimeter
Display Limits
200 nA
10 liA
50 nA
100 tiA
100 kn ± 0.01%
1.0000 V
5.0000 V
10.000 V
9.98- 10.02
pA
49.95 - 50.05
pA
99.92 - 100.08 pA
2 mA
.1 mA
5 mA
1 mA
1 kn ± 0.01 %
.10000 V
.50000 V
1.0000 V
.0998-.1002
mA
.4995 - .5005
mA
.9992 - 1.0008 mA
20 mA
1 mA
5 mA
10 mA
1 kn ± 0.01%
1.0000 V
5.0000 V
10.000 V
.998 - 1.002
mA
4393 - 5.007
mA
9.988 - 10.012 mA
200 mA
10 mA
50 mA
100 mA
ion 0.01%
.10000 V
.5000
V
1.0000 V
9.93- 10.07
mA
49.69 - 50.31
mA
99.39 - 100.61 mA
2000 mA
100 mA
500 mA
1000 mA
1 no.o2 %
.10000 V
.50000 V
1.0000 V
99.3- 100.7
mA
496.9 - 503.1
mA
9933 - 1006.1 mA
b. Connect the 100 kilohm ± 0.01% resistor in the
position as shown.
c. Set the Multimeter function to DCA (
A) and
range to 200 fxA. Adjust the power supply output for a
differential voltmeter reading of 1.000 V. The Multimeter
should indicate 99.98 to 100.02 /rA.
d. Check all the Multimeter ranges, using the values of
and differential voltmeter readings shown in Table 5-3.
Ihe Multimeter display should indicate within the limits
provided.
5-10. Ohms Accuracy Test.
5-11. A precision resistive decade box will be required for
this test. It should be calibrated and have a known accuracy
of .005%.
a. Connect the equipment as shown in Figure 5-2.
Table 5-4. Ohms Accuracy Test.
DIGITAL MULTIMETER
hp 3465
FIXED
RESISTORS
MAY BE
SUBSTITUTED.
RESISTANCE
DECADE
BOX
Figure 5-2. Ohms Accuracy Test.
b. Set the Multimeter function to OHMS (C2) and check
all the ranges in Table 5-4 using the decade box to supply
the indicated resistances. The Multimeter display should
indicate within the limits provided.
5-12. AC Voltage Accuracy Test.
5-13. An AC Calibrator and High Voltage Amplifier will
be required for the following tests.
Multimeter
Resistive Decade
Multimeter
Range
Setting
Display Limits
200 n
10 n
9.98-10.02
n
50
n
49.97 - 50.03
n
100 n
99.96-100.04
n
2 kn
100
n
.0999 -.1001
kn
500
n
.4998 - .5002
kn
1
kn
.9997 - 1.0003 kn
20 kn
1
kn
.999 - 1.001
kn
5 kn
4.998 - 5.002
kn
10 kn
9.997 - 10.003 kn
200 kn
10 kn
9.99-10.01
kn
50 kn
49.98 - 50.02
kn
100 kn
99.97-100.03 kn
2000 kn
100 kn
99.9-100.1
kn
500 kn
499.8 - 500.2
kn
1000 kn
999.7 -1000.3 kn
20 M
1 Mn
.998 - 1.002
Mn
5 Mn
4394 - 5.006
Mn
10 Mn
9389 - 10.011 Mn
a. Set the Multimeter function to ACV (~V). Cormect
the AC Calibrator between the Vf2 terminal and COM
terminal. Be sure to connect the Calibrator sense leads.
b. Check the voltage ranges listed in Table 5-5 at each
frequency listed. The Multimeter should indicate within the
limits provided.
5-14. AC Ammeter Accuracy Test
5-15. An AC Calibrator, a 3450B Digital Voltmeter and
discrete resistors (Ra) indicated in Table 5-6 are required
for this test. Even though lesser accurate resistance values
are required for this test, it is expedient to use the resistors
specified in Table 5-1.
a. Set the Multimeter function to ACA (~ A) and range
to 200 /lA. Connect the equipment as shown in Figure 5-3
using a discrete resistor for R^. (To select R^. note the
5-2

Advertisement

Table of Contents
loading