_G@SW-9320
12. RECORD/PLAYBACK
FREQUENCY
RESPONSE
ADJUSTMENT
Test tape
Test
point
Adjustment
Adjust for
Confirmation
Adjust
response | of the dub-
10KHz
flat.
after ad-
justment.
At 1kHz/10kHz
20A, 20B point adjustment
of the input so as to 580mV-25dB.
MTT-5511
MTT-5561
MTT-5571
Record/Playback
Head
Figure 15 Record/Playback
Frequency
Response
Adjustment
Connection
Diagram
—~9—