Rom; Serial & Parallel Port Assignments - Philips PCL304 Service Manual

Notebook personal computer
Table of Contents

Advertisement

Conventional Memory:
Extended Memory:
Expanded Memory:
Shadow Memory:
NOTE:
2.2.4 ROM
In the area from 512 Kbyte to 576 Kbyte
(0E0000 h - OEFFFF h)
2.2.5 VO Connections
embedded hard disk drives
DB-9P, serial port connector. Via the SETUP program
this port can be disabled, or can be configured as
PORT 1. PORT 1 has the base I/O address 3F8h.
For COM port assignments, refer to subsection
2.2.4.1.
CN:
2-3
Ji:
DP-25P, serial port connector. Via the SETUP program
this port can be disabled, or can be config/ted as
PORT 2. PORT 2 has the base I/O address of 2F8h.
For COM port assignments, refer to subsection
2.2.4.1.
DB-25S, parallel port connector. Via the SETUP pro-
gram this port can be disabled, or can be ¢Onfigured
as PORT 2. PORT 2 has the base I/O address 378h.
For LPT port assignments, refer to subsection
2.2.4.1.
CN4:
CN1:
DB-15S, analog video connector. This pot can be
disabled/ enabled via software, [Fn] + [F10}.
CN14: 6-pin, Mini-Din type keypad connector. This port sup-
ports AT compatible types only.
CN13: 6-pin, Mini-Din type PS/2 Mouse connector. This port
supports PS/2 compatible types only.
2.2.6 Serial And Parallel Port Assignments
The serial ports require eight consecutive I/O addresses for
access to the control and status registers. COM1is always
assigned to the highest /O address (when using only one
port, this may be either on 2F8h or 3F8h). If two serial ports
are installed COM2 is assigned to the next lower I/O ad-
dress (COM1 is assigned to 3F8h and COM2 is assigned to
2F8h). The table on the next page gives the three possible
configurations:
Configuration
Base
Port
Base
Port
Addr.
Addr.
1
-
-
2F8h
COM1
2
3F8h
COMi
-
-
3
3F8h
COM1
2F8h
COM2
Fig. 2-3
The parallel ports require three consecutive I/O addresses
for access to the control, status and data registers. LPT1 is
always assigned to the highest /O address available (when
using one parallel port, this may be on 278h, 378h or
3BCh). If two parallel ports are installed, LPT2 is assigned
to a lower V/O address. If three parallel ports are installed,
LPT3 is assigned to the lowest I/O address. The following ta-
ble gives the seven possible configurations:
Configu-
Base
Port
Base
Port
Base
Port
ration
Addr.
Addr.
Addr.
1
-
-
-
-
278h
LPTi
2
-
-
378h
LPT1
-
-
3
3BCh
LPT1
-
-
-
-
4
-
-
378h
LPT1
278h
LPT2
5
3BCh
LPT1
-
-
278h
LPT2
6
3BCh
LPT1
378h
LPT2
-
-
7
3BCh
LPT1
378h
LPT2
278h
LPT3
Fig. 2-4