14
3.3 Electrical Interface
3.3.1 RJ-45 Socket
Ethernet Socket * 1pcs
Serial Socket * 1pcs
3.3.2 Toggle Switch and Push Button
RJ-45
1
2
3
4
5
6
7
8
Case
RJ-45
1
2
3
4
5
6
7
8
Case
Toggle Switch Status
Up
Down
Push Button
Push and detach
Reset
Push for 5sec
PLC Reset
Push for 20sec
Factory Reset
Push hold and
IAP mode
Power Reset
Signal Name
TD+
TD-
RD+
-
-
RD-
-
-
Shield
Signal Name
D+
D-
GND
/ISP
-
GND
TXD
RXD
Shield
Module is
RUN
STOP
Module is
Description
Reset CODESYS PLC program and
make the program be in the stop status.
Erase CODESYS PLC program and
retain memory.
Erase CODESYS PLC program and
Network parameter reset.
Firmware download via Firefox.
HX-RIO3 Series
Description
Transmit +
Transmit -
Receive +
Receive -
Description
RS485 D+
RS485 D-
/ISP
RS232 TXD
RS232 RXD
Description
PLC Run
PLC Stop