Aquaclean Water Filter Ep Models; Descaling Request Ep Models - Philips 4000 Service Manual

Hide thumbs Also See for 4000:
Table of Contents

Advertisement

PHILIPS 4000
Hardness
Water hardness
Soft (up to 7°dH)
1
Medium (7° - 14°dH)
2
Hard (15° - 21°dH)
3
Very hard (over 21°dH)
4
The default water hardness level is 4. Each litre of water corresponds to approximately 2,000 pulses.

3.12. AquaClean water filter EP models

The AquaClean filter is designed to reduce limescale deposits in the coffee machine and provide filtered water to
preserve the aroma and flavor of each cup of coffee. By using a series of 8 AquaClean filters, there is no need to
descale the machine for 5000 cups (It depends both on the type of coffee used, rinsing and cleaning programs).
We
recommend
chine to the maximum before using 5 L of water. The machine display will indicate
when the filter needs to be replaced. The maximum limit is equivalent to 110 L of water.
The conditions related to the filter work environment (water, therefore, an active environment for bacteria
and microorganisms), require the replacement with a minimum frequency (we suggest 3 months from the
activation to ensure the best performance). The filter starts' working from the time is filled with water and
continues working even with the machine off. It cannot be deactivated manually, as it must end its life cycle.
At the filter activation the display shows the icon with the percentage of use:
- Initially 100% then decreasing.
When the autonomy of the current filter becomes less than 8 L of water the display
shows:
- The icon flashing slowly. It means 10%.
When the autonomy of the current filter becomes less than 2 L of water the display
shows
- The icon flashing quickly. It means 0%.
After a maximum of 110 L of water supplied the flashing light turn off and the
machine needs to be descaled.
The water tank of all Minuto EP models is designed to fit only with the AquaClean filter.

3.13. Descaling request EP models

The first activation must take place before dispensing 5,00 L of products, otherwise
hardness setting and calculates as in the table "Descaling cycle frequency with brita filter (HD models).
Hardness
Filter number
From 1/8 to
7/8
Indifferent
8/8
If after descaling or after the use of a filter this is not reactivated , the machine recognizes the water hardness setting and
calculates as in the table "Descaling cycle frequency with brita filter (HD models).
Descaling cycle frequency with brita filter (HD models)
installing
the
water
Descaling cycle frequency with AQUACLEAN filter (EP models)
Percentual on display 10%
the icon flashes slowly.
(encourage the consumer
to buy the filter)
8,00 l of product remaining
Without water filter
240 litres (480,000 pulses)
120 litres (240,000 pulses)
60 litres (120,000 pulses)
30 litres (60,000 pulses)
filter
AquaClean
Percentual on display
0% the icon flashes
quickly. (tell the consu-
mer to change the filter)
2,0 l of product
remaining
03 OPERATING LOGIC
With water filter
480 litres (960,000 pulses)
240 litres (480,000 pulses)
120 litres (240,000 pulses)
60 litres (120,000 pulses)
the
first
use
of
the machine recognizes the water
MAX Quantity wa-
ter, the icon turns
off. (replace filter)
Replace filter (you
can not turn off)
110 l
the
ma-
Descaling
8/8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents