Hitachi RCUE40AG2 Service Manual page 19

Air cooled water chillers, cooling only and heat pump, cooling capacity 106/112 kw - 585/556/1030 kw
Table of Contents

Advertisement

Product range and
specifications
MODEL
Cooling Capacity
Heating Capacity
Total Power input in cooling
Total Power input in heating
Height
Height
Outer Dimension
Width
Depth
Depth
Cabinet colour
Net weight
Compressor type
Models
Quantity
Oil heater
Capacity control
Water side heat exchanger
Air side heat exchanger
Fan Motor (pole)
Quantity
Refrigerant type
Flow control
Number of independent circuits
Quantity of refrigerant
Oil type
Water pipe connection
Control system
Chilled water outlet temperature
Heated water outlet temperature
Condenser air inlet temperature
Evaporator air inlet temperature
Permissible water pressure max.
Permissible water pressure max.
Permissible water pressure max.
Safety and protection devices
Power suply
NOTES:
(1) The nominal cooling capacities are based on the European Standard EN12055.
Chilled Water Inlet / Outlet Temperature : 12/7 ºC
Condenser Inlet Air Temperature : 35 ºC
(2) The nominal heating capacities are based on the European Standard EN12055.
Heated Water Inlet / Outlet Temperature : 40/45 ºC
Evaporator Inlet Air Temperature : 6 ºC (WB)
page 17
SMGB0003 rev.0-01/2007
RHUE80AG2
kW
195
kW
185
kW
69.6
kW
67.7
mm
2.430
mm
1.900
mm
2.500
-
Kg
1.950
-
-
60ASC-Z
-
1
W
150
-
%
-
-
kW
-
6
-
-
-
1
-
64
-
JAPAN ENERGY FREOL UX300 (Ester)
3" Victaulic (1xInlet/
3" Victaulic (1xInlet/
Inch
1xOutlet)
1xOutlet)
-
ºC
ºC
ºC
ºC
DB: -9.5~21/ WB:-10~15.5 for heating operation
MPa
Reverse Phase Protection, Fuse and Thermal Relay for Compressor,
Reverse Phase Protection, Fuse and Thermal Relay for Compressor,
Reverse Phase Protection, Fuse and Thermal Relay for Compressor,
Reverse Phase Protection, Fuse and Thermal Relay for Compressor,
Reverse Phase Protection, Fuse and Thermal Relay for Compressor,
Internal Thermostat for Compressor, Compressor Oil Heater,
Fuse and Internal Thermostat for Fan Motor, Control Circuit Fuse,
-
High Pressure Switch, Low Pressure Control,
High Pressure Relief Valve, Discharge Gas Temperature Control,
Suction Gas Temperature Control, Freeze Protection Control
and Compressor Operation Hour Meter
and Compressor Operation Hour Meter
and Compressor Operation Hour Meter
-
RHUE100AG2
RHUE120AG2
246
296
254
305
85.4
104.5
89.0
108.6
2.430
2.430
1.900
1.900
3.800
3.800
Natural Grey
3.050
3.250
Semi-Hermetic screw type
40ASC-Z
50ASC-Z
2
2
150x2
Continuous Capacity Control
Continuous Capacity Control
Continuous Capacity Control
15~100
Brazing plate type
Multi-Pass cross fi nned tube
0.38 (8)
8
8
R407C (Factory charged)
Electronic expansion valve
2
2
92
82
3" Victaulic (2xInlet/2xOutlet)
Micro-processor control
-10 (Option) 5~15
35~55
-15~46 for cooling operation
1.0
3~, N/380-415V/50Hz
RHUE140AG2
338
1
1
371
119.6
135.5
2.430
1.900
5.500
3.670
60ASC-Z
2
12
2
96

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents