Integral Keypad - Hmi - Philips CVW300G2 Installation Manual

Variable speed drive for electric traction
Table of Contents

Advertisement

Available languages

Available languages

Variable Speed Drive for Electric Traction
In case the contactor used between the CVW300G2 and the battery
has an auxiliary contact, its wiring must be done according to
7 on page
10.
Figure 7: Contactor wiring
NOTE!
In case the contactor does not have an auxiliary
contact, it is necessary to short the pins 17 and 18
of XC10; otherwise, the inverter will show fault F185.
INTEGRAL KEYPAD – HMI
The HMI for the CVW300G2 is supplied as an accessory and must
be purchased separately. For detailed information please refer to the
CVW300G2 user's manual.
1. Press this key to go
back to the previous
- USB communication
group.
port
2. Press this key to go to
the next parameter.
3. Press this key
to increase the
parameter value.
1. Press this key to
go back to the
monitoring mode.
2. Press this key to
go back to the
previous level in the
parameterization
mode.
3. Press this key to
cancel the new value
and go back to the
previous level.
- Press this key to
define the motor
rotation.
This option is active
when:
P0223 = 2 or 3 in
LOC and/or
P0226 = 2 or 3 in
REM.
- Press this key to
toggle between
LOCAL and REMOTE
mode.
This option is active
when:
P0220 = 2 or 3.
- Press this key to accelerate the motor up to the speed set in P0122. The motor
speed is maintained while the key is pressed. When the key is released the
motor decelerates up to its complete stop.
This function is active when all the following conditions are met:
1. Start/Stop = Stop.
2. General Enable = Active.
3. P0225 = 1 in LOC and/or P0228 = 1 in REM.
Figure 8: Operator keys
10 | CVW300G2
All manuals and user guides at all-guides.com
Figure
Menu
(parameters
group
selection)
– only one
parameter
group is
shown
ateach time.
Parameter groups available at the Menu:
ƒ
PARAM: all parameters.
ƒ
READ: only the reading parameters.
ƒ
MODIF: only the parameters changed compared to the factory
default.
ƒ
BASIC: basic application parameters.
ƒ
MOTOR: parameters related to motor data control.
1. Press this key to
ƒ
I/O: parameters related to the digital and analog inputs/outputs.
decrease the speed.
ƒ
NET: parameters related to the communication protocol.
2. Press this key to go to
ƒ
HMI: parameters for the keypad configuration.
the next group.
3. Press this key to go
ƒ
SPLC: parameters related to the SoftPLC function.
back to the previous
ƒ
STARTUP: parameters for the oriented startup.
parameter.
4. Press this key
to decrease the
Inverter status:
parameter value.
ƒ
LOC: command source or local reference.
ƒ
1. Press this key to enter
REM: command source or remote reference.
in the programming
ƒ
: motor rotation according to the arrows.
mode.
ƒ
CONF: configuration. It indicates that the inverter is in the Oriented
2. Press this key to select
the desired parameter
Start-up routine or with in compatible parameter programming.
group.
Refer section 5.6 Incompatibility Between Parameters in the user's
3. Press this key to show
the parameter.
manual of the CVW300G2.
4. Press this key to save
ƒ
SUB: Battery undervoltage.
the parameter value.
ƒ
RUN: inverter enabled and/or DC braking activated.
- Press this key to
accelerate the motor
according to the
acceleration ramp time.
This option is active
when:
P0224 = 0 in LOC and/or
P0227 = 0 in REM.
- Press this key to
decelerate the motor
according to the
deceleration ramp time.
This option is active
when:
P0224 = 0 in LOC and/or
P0227 = 0 in REM.
NOTE!
It is necessary to set the password at P0000 for
parameter modification; otherwise the parameters
contents can only beviewed.
The default password for P0000 is 5. It is possible
to change the password at P0200. Refer to the
CVW300G2 user's manual.
Local/Remote
Motor
(commands and
Inverter
rotation
references source)
status
Main display
Figure 9: Display sections
Secondary
display
Variable
unit (shows
the value
of the main
display)
Variable
monitoring
bar graph

Advertisement

Table of Contents
loading

Table of Contents