Download Print this page

Sony DPS-F7 Service Manual page 13

Digital dynamic filter plus

Advertisement

SECTION 3
DISASSEMBLY
Note:
Follow the disassembly procedure in the numerical order given.
3-1. REMOVAL OF CASE
@ +BV3~x6
@ +«BV3x6
MAIN unit
SECTION 4
ADJUSTMENT
LED Level Adjustment
Adjusting points :MAIN Board
Setting:
€)
attenuator
47k 2
[e)
Adjusting method:
1,
INPUT Volume:MAX
2.
Input — 30dBs, 1kHz signal to UN BALANCE input.
3.
Adjust RV401
(CH-1) and RV451 (CH-2) so that the LED display of
the level meter lights until OdB.
.
(Conductor side)

Advertisement