Focus/Tracking Gain Adjustment
A
frequency
response
analyzer
is necessary
in
order to perform this adjustment exactly.
However,
this gain has a margin, so even if it is
slightly off, there is no problem.
Therefore, do not
perform this adjustment.
Focus/tracking gain determines the pick-up follow-
up (vertical
and horizontal)
relative
to mechanical
noise
and mechanical
shock when
the 2-axis device
operate,
However, as these reciprocate, the adjustment is at
the point where both are satisfied.
@
When
gain is raised, the noise
when the
2-axis
device operates increases.
@
When
gain is lowered,
it is more
susceptible to
mechanical shock and skipping occurs more easily.
@
When gain adjustment is off, the symptoms below
appear.
low or high
@ The time until music starts
becomes longer for STOP
=P
PLAY or automatic
selection (Hed PR buttons
pressed.
(Normally takes
about 2 seconds.)
e Music does not start and
disc continues to rotate
for STOP =>
PLAY or
automatic selection (Hed
bi buttons pressed.)
e Sound is interrupted dur-
ing PLAY.
Or time count-
er display stops progress-
ing.
e More poise during 2-axis
device operation.
The following is a simple adjustment method.
— Simple Adjustment —
Note:
Since exact adjustment cannot be performed, remem-
ber the positions of the controls before performing the
adjustment.
If the positions after the simple adjust-
ment are only a little different, return the controls to
the original position.
Procedure:
1. Keep the set horizontal.
If the
set
is not
horizontal,
this adjustment
cannot be performed due to the gravity against
the 2 axis device.
2. Insert disc (YEDS-18) and press
®» PLAY button.
3. Connect the oscilloscope between IC701
pins 62)
and
6) .
4. Adjustment
RV705
so
that
the
waveform
is as
shown in the figure below. (focus gain adjustment)
@
Incorrent
Examples (DC level changes more than
on adjusted waveform)
low focus gain
—-OV
VOLT/DIV:
TIME/DIV:
2mS
VOLT/DIV:
TIME/DIV:
2mS
250mvVv
700 mV
100 mV
VOLT/DIV:
100
mv
TIME/DIV:
2mS
5. Connect
the oscilloscope between IC701
pins
@)
and
26) :
6. Adjust RV704 so that the waveform is as shown in
the figure below. (tracking gain adjustment)
VOLT/DIV: 1V
TIME/DIV: 2ms
OV
@
Incorrect Examples (fundamental wave appears)
low tracking gain
VOLT/DIV:
1V
TIME/DIV:
2mS
OV
high tracking gain
(higher fundamental wave than for low gain)
VOLT/DIV:
1V
TIME/DIV:
2mS
Ov
Adjustment Location: CD main board (conductor side)
Remove the solder bridge while -
adjusting the tracking gain.
(After adjustment make the
solder bridge.)
oscilloscope
(DC range)
Remove the solder bridge while
adjusting the focus gain.
—— (After adjustment make the
solder bridge.)
RV705
1C701 pin @
1C701 pin @
IC701 pin @
RV704