Mitsubishi Electric FR-A520-0.4K-NA Instruction Manual page 207

Transistorized inverter
Hide thumbs Also See for FR-A520-0.4K-NA:
Table of Contents

Advertisement

Protective/alarm functions
Ambient temperature
Ambient humidity
Storage temperature
(Note 3)
Ambience
Altitude, vibration
Note: 1. Jog operation may also be performed from the operation panel or parameter unit.
2. Not provided for the FR-A520-11K to 55K and FR-A540-11K to 55K which do not have a built-in
brake circuit.
3. Temperature applicable for a short period in transit, etc.
Overcurrent shut-off (during acceleration, deceleration, constant speed), regenerative
overvoltage shut-off, undervoltage, instantaneous power failure, overload shut-off (electronic
overcurrent protection), brake transistor alarm (Note 2), ground fault current, output short
circuit, main circuit device overheat, stall prevention, overload alarm, brake resistor overheat
protection, fin overheat, fan fault, option fault, parameter error, PU disconnection
Constant torque: -10°C to +50°C (14°F to 122°F) (non-freezing)
(-10°C to +40°C with FR-A5CV
Variable torque:
-10°C to +40°C (14°F to 104°F) (non-freezing)
(-10°C to +30°C with FR-A5CV
90%RH or less (non-condensing)
−20°C to +65°C (−4°F to +149°F)
Indoors. (No corrosive and flammable gases, oil mist, dust and dirt.)
Maximum 1000m (3280.80 feet) above sea level for standard operation.
After that derate by 3% for every extra 500m up to 2500m (91%).
193