GE PROFINET PACSystems RX3i Quick Start Manual page 2

Controller module
Hide thumbs Also See for PROFINET PACSystems RX3i:
Table of Contents

Advertisement

2
GFK-2573K
PNC Specifications
PROFINET Support
RX3i CPU Compatibility
Power Requirements
Operating Temperature Range
Number of Port Connectors
Micro USB Connector
LAN
Maximum I/O Memory
CPU Status Bits
PROFINET I/O Device Data Update Rates on
the PROFINET LAN
Number of IP addresses
Number of MAC Addresses
System Maximum Limits
PNCs per RX3i CPU
I/O-Devices per I/O-Controller
I/O-Devices per Network
I/O-Devices per RX3i CPU
I/O-Controllers per network
Number of PROFINET Slots per device
Number of PROFINET Subslots per slot
Number of PROFINET Submodules per RX3i
CPU
Programmer Limits
Number of I/O-Controllers
Number of I/O-Devices
Total number of devices
Hot-swappable
For product standards, general operating specifications, and installation requirements, refer to GFK-2314, PACSystems
RX3i System Manual.
IC695PNC001-AJ PROFINET Controller Module
PROFINET Version 2.2 General Class A I/O-Controller.
Redundantly controlled operation conforms to PROFINET V2.3 Type S-2
System Redundancy.
CPU315 or CPU320, with firmware version 7.0 or higher
CPE305/CPE310 with firmware version 7.10 or higher
Simplex or redundantly-controlled PROFINET I/O requires CRU320 release
8.40 or higher.
3.3 V:
0.5 A with no SFP devices installed
1.2 A maximum (two SFP devices installed, 0.35 A per SFP device)
5 V:
1.5 A maximum
0 to 60°C maximum surrounding air temperature without a fan. A lower
maximum temperature may be required depending on PNC location and
SFP population. Refer to the section, Operating Range for Air Temperature in
GFK-2571, PACSystems RX3i PROFINET Controller Manual.
Two RJ-45 and two SFP Cages
(SFP devices not included, available separately)
One, for communication with a computer using Command Line Interface.
IEEE 802.2 Logical Link Control Class I
IEEE 802.3 CSMA/CD Medium Access Control 10/100/1000 Mbps
128 Kbytes of combined input/output memory per PROFINET Controller
32
Configurable: 1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms, 64 ms, 128 ms, 256 ms
and 512 ms
One
Five. One per external port and one internal.
Four. Must be located in main rack. Cannot be located in a remote node.
128 per PROFINET Controller (Configured as an MRP Manager, the PNC is
limited to managing no more than 63 MRP Clients).
255 per network, spread across up to 8 IO-Controllers
255 per RX3i CPU, spread across up to 4 PROFINET Controllers
8
256
256
2048
128 (32 RX3i CPU targets × 4 IO-Controllers per RX3i CPU)
4080 (255 per network × 16 PROFINET networks)
4208 (does not include backplanes, power supplies, or I/O modules)